background image

6/20

NT 1001-F00 10.10 C12 A - C18 A  e

2. INSTALLATION

POSSIBLE POSITIONS

JACKET CONNECTION (variant)

1" CYLINDER GAS

LIQUID

STEAM

SUCTION

DISCHARGE

STANDARD

STANDARD

The C Series pump is a selfpriming volumetric PD pump.

Therefore, the pump must not run on a circuit with a closed
valve. This is valid both for the suction circuit and for the dis-
charge circuit.

2.1 Orientation of  the pump ports

The discharge port may be oriented in various positions.

If the port positions needs to be changed at any time,
see the corresponding paragraph.

2.2 Direction of  rotation

When looking at the shaft, the rotation will be clockwise.
When looking at the front cover, the direction of rotation
will be anti-clockwise. An arrow situated on the bearing
housing indicates the correct direction of rotation.

Verification of the correct rotation direction :

Turn the pump the wrong way is not dangerous for the
pump.

2.3 Protection of  the pump installation

• For ease of maintenance, it is a good idea to place iso-

lation valves before and after the pump. The sizing of
these valves must correspond to the diameter of the
pipes.

• Before any start-up, during operation or complete stop-

ping of the pump, make sure the valves are open.

• During stop periods, with the pump full of product,

either the suction or discharge circuit must be left open
to enable expansion or contraction of the pumped pro-
duct through reheating or cooling. If this instruction is
not complied with, The bellows may be damaged and
lead to premate failure.

• The bearing must be ventilate at all times, therefore the

breather mounted on the bearing must be re-used.
Never put the bung on.

• In case of flodded suction, it is possible to install a

liquid detector in the place of the transmission breather
(see § options). This detector will enable the user to be
informed in the case of failure of the bellows. In the
case of detection, the installer must make sure the
pump is stopped and the isolating valves are closed.
Non compliance with this instruction can lead to the
pumped product being spilt outside the pump.

• It is possible to have a puncture detection system with

double-walled bellows : an inert gas is maintained under
pressure between the 2 walls and said pressure is per-
manently monitored. A signal is dispatched immediately
should a wall become punctured (see § OPTIONS).

• The stop time may lead to cooling of the product in the

pump and therefore to an increase in viscosity. If this is
the case, we recommend re-starting the pump at a
speed adapted to this new viscosity (starting pump).
Once the product arrives in the pump at the installation
definition temperature, the pump may run at the speed
specified for this application.

NOTICE

C-Series pumps remains drainable whatever
position is chosen for the inlet port, but the
outlet port must be at the bottom (position 4)
to keep the self-draining capability.

Содержание C12 A

Страница 1: ...NCE INSTRUCTIONS 1001 F00 e Section 1001 Effective October 2010 Replaces August 2010 Original instructions Your distributor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com ...

Страница 2: ...s adjustment 16 10 2 Changing the spring 16 10 3 Replacement of the seals 16 11 HEATING JACKET OPTION 17 11 1 Replacement of the jacket seal 17 11 2 Bleed included with jacket option 17 12 DRAINING OF BEARING 18 13 OPTIONS 19 13 1 Liquid detector 19 13 2 Bellow monitoring system 19 14 CERTIFICATE OF CONFORMITY 20 TABLE OF CONTENTS Page ECCENTRIC PISTON PUMP MOUVEX PRINCIPLE SAFETY INSTRUCTIONS STO...

Страница 3: ...ate Filling Breather Draining of transmission Draining of main body 1 4 BSP option Draining of front cover 1 4 BSP option Jacket variant Mounting point for probe M6 threaded width max 8 mm C P R V V1 V2 EV S 4 equidistant ablong holes Weight kg lb PN16 Type 01 Shrinked on and welded pipe PN20 Type 12B Shrinked on and welded pipe ...

Страница 4: ...ection NOTA Setting of detecion levels is done in factory and do not have to be modified For other dimensions report to pump dimensional drawing The dismantling of the transmission could be done only in factory Wiring diagramm Connector Do not use S2 Normal operation CAUTION A BAD CONNECTION CAN DESTROY THE SENSOR ...

Страница 5: ... modified For other dimensions report to pump dimensional drawing The dismantling of the transmission could be done only in factory With falling pressure 3 2 opens CAUTION Incorrect connection can lead to a flammability risk ineffective monitoring possible damage to the sensor Connection diagram Ex free Zone Ex Zone 1 or 2 21 or 22 Supply voltage Output Yellow Green Microswitch ...

Страница 6: ...expansion or contraction of the pumped pro duct through reheating or cooling If this instruction is not complied with The bellows may be damaged and lead to premate failure The bearing must be ventilate at all times therefore the breather mounted on the bearing must be re used Never put the bung on In case of flodded suction it is possible to install a liquid detector in the place of the transmiss...

Страница 7: ...ficiently resis tant to absorb the stresses caused by the motor driven pump unit without deformation if it is made of concrete it must comply with the BAEL 91 standard If the unit is fastened using securing lugs or bolts it must be carefully wedged to avoid deforming the frame while the bolts are tightened A deformed frame would apply damaging stresses on the pump and the drive mecha nism and misa...

Страница 8: ... on the unit or the pump after fastening on the foundations after fastening the pipes after the pump has been operated at the normal operating temperature Where the pumps are supplied assembled as a unit the motor and pump shafts have been perfectly aligned in the factory before delivery but they must be systemati cally controlled on acceptance at the site and realigned if necessary To do this do ...

Страница 9: ... OR DEATH WARNING Do not operate without guard in place IT IS IMPERATIVE THAT THE HYDRAULIC PRESSURE IS RELEASED BEFORE EACH MAINTENANCE OPERATION TO AVOID PERSONAL INJURY OR MATERIAL DAMAGE WARNING Hazardous pressure can cause personal injury or property damage TAKE ALL NECESSARY MEASURES TO RENDER ANY START UP EVEN ACCIDENTAL OF THE PUMP DURING THE WORK IMPOSSIBLE WARNING Any unforeseen start up...

Страница 10: ... be dangerous and may provoke bodily injuries or material damages DISCONNECTING THE FLUID OR PRESSU RE CONTAINMENT COMPONENTS DURING PUMP OPERATION CAN CAUSE SERIOUS PERSONAL INJURY DEATH OR MAJOR PROPERTY DAMAGE WARNING Hazardous pressure can cause personal injury or property damage IF PUMPING HAZARDOUS OR TOXIC FLUIDS THE SYSTEM MUST BE FLUSHED PRIOR TO PERFORMING ANY SERVICE OPERATION WARNING H...

Страница 11: ... 70 mm and unscrew the nut 304 and its seal 305 With the help of a hub puller extract the piston 301 Remove the cylinder 201 and the seals 113 306 and 307 It is important to keep a good grip on the piston its rotation could lead to deterioration of the bellows Before any dismantling make sure that the pump has been drained and take the necessa ry measures to avoid starting up No start up even acci...

Страница 12: ...aximum acceptable wear dimensions defined in the table below are reached As changes in the pump s efficiency depend on the conditions of use pressure rotation speed liquid pum ped etc MOUVEX recommends that users define the monitoring ranges and the preventive maintenance schedule according to their own experience Piston 301 mm inch Cylinder 201 mm inch C12 New dimension 9 0 354 50 1 969 Minimum w...

Страница 13: ...s of the end of the transmission hub 596 Place thread locking adhesive Loctite 243 or equivalent on the thread of the transmission hub 596 Check the state of the seal 305 replace it if necessary Hold the piston 301 with a monkey wrench opening 70 mm and screw the nut 304 after first fitting the seal 305 Check the state of the seal 305 and replace it if necessary Re mount the front cover 401 while ...

Страница 14: ...ismantling taking care to correctly position the seal 113 and main body 101 The screws 111 must be re mounted with thread locking adhesive Loctite 243 or equivalent 4 x M16 Assembly torque 100 Nm Under preventive maintenance every 150 millions of cycles duty we suggest transmission replacement In this case The transmission delivered is equipped with a tubular foam protection We advise leaving this...

Страница 15: ...Standard oil provided by MOUVEX CS05 Food synthe tic oil Safety data sheet is supplied with the new pump and on inquiery Other oil provided by customer FOOD SYNTHETIC GREASE Compulsory reference because compatible with the standard MOUVEX bearing oil 518 507 715 608 725 THEPUMPLUBRICANTISVERYSLIPPERY AND MAY CAUSE SERIOUS INJURY ANY SPILLS MUST BE CLEANED UP CAUTION Slippery lubricant Spills shoul...

Страница 16: ...ing care to the thrust produced by spring 804 Block the unit comprising the pressure screw nut 828 in a vice Using a pin drift remove pin 831 Remove the nut 834 Remove the screw 826 the spring 829 the seal 837 and the washer 838 Replace seals and reinstall in reverse order of disas sembly NOTICE When assembling seal 837 we recommend covering the pin hole on shaft 826 with adhesive tape to avoid da...

Страница 17: ...ng an Allen key unscrew the screws 122 Check the state of the seal 121 replace it if necessary Reassembly is in reverse order of disassembly WARNING Hazardous pressure can cause personal injury or property damage DISCONNECTING THE FLUID OR PRESSU RE CONTAINMENT COMPONENTS DURING PUMP OPERATION CAN CAUSE SERIOUS PERSONAL INJURY DEATH OR MAJOR PROPERTY DAMAGE Before carrying out any work make sure t...

Страница 18: ...eck oil level that the level is between 1 and 5 mm above the schaft Screw back the breather 715 Standard oil provided by MOUVEX CS05 Food synthe tic oil Safety data sheet is supplied with the new pump and on inquiery Other oil provided by customer Oil level Min 1 mm Max 5 mm Temperature of product pumped heating product Draining interval running hours 150 C T 160 C 800 135 C T 150 C 1 500 120 C T ...

Страница 19: ...he bellow ply A pressure switch is connected on the bellow s gas filling cavity and all the circuit is sealed This operation is done by the factory and any technical operation will break the sealings see picture and avoid the warranty The gas pressure is 0 2 bar 2 9 psi above the maxi mum acceptable pressure on the bellow under working condition Any puncture in either one of the two metallic bello...

Страница 20: ...1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 x ATEX Directive 94 9 EC 23 march 1994 as transposed by the national legislation concerning equipment intended to be used in explosive atmospheres Conformity obtained by application of the standards NF EN 1127 1 1997 NF EN 13463 1 2009 NF EN 13463 5 2009 ATEX Certification delivered by INERIS Notified Body INERIS Parc Technologique Alata 60550 Vern...

Отзывы: