18/20
NT 1001-F00 10.10 C12 A - C18 A e
•
Drain the transmission following the board below :
•
Data with standard MOUVEX oil :
•
Data with other customer oil :
the drawing interval is
defined by the customer (tests results) regarding the oil
specifications and the pump conditions.
• Drain the pump by removing the drain bung with its seal
773-774
and the breather
715
.
• Replace the drain bung and its seal.
• Fill the transmission with 2 litres of oil*.
• Check oil level that the level is between 1 and 5 mm above
the schaft.
• Screw back the breather
715
.
* Standard oil provided by MOUVEX : CS05 Food synthe-
tic oil (Safety data sheet is supplied with the new pump
and on inquiery)
.
*
Other oil provided by customer.
Oil level
Min : 1 mm
Max : 5 mm
Temperature of product
pumped / heating product
Draining interval
(running hours)
150 °C < T ≤160 °C
800
135 °C < T ≤150 °C
1 500
120 °C < T ≤135 °C
3 000
100 °C < T ≤120 °C
6 000
80 °C < T ≤100 °C
12 000
T ≤ 80 °C
24 000
CAUTION
Slippery lubricant.
Spills should be
cleaned up.
THE PUMP LUBRICANT IS VERY SLIPPERY
AND MAY CAUSE SERIOUS INJURY. ANY
SPILLS MUST BE CLEANED UP.
12. DRAINING OF BEARING