background image

99286GB - 

06/14 - a_013334

SAFEGUARDING YOUR  SECURITY

www.mottura.it 

Содержание Xmode F1.0

Страница 1: ...POWERED ELECTRONIC LOCK OPERATION AND MAINTENANCE INSTRUCTIONS USER MANUAL GLUE THE LOCK SYSTEM CODE LABEL HERE SYSTEM CODE RECHARGEABLE M 2 0 F1 0 ...

Страница 2: ...SABLING SERVICE TAG KEYS 5 4 RESETTING SERVICE TAG KEYS 5 5 DELETING INDIVIDUAL TAG KEYS 5 6 DELETING ALL TAG KEYS 6 LOCK OPERATION MODES 10 6 1 PROGRAMMING LOCK OPERATION MODES 6 2 ACTIVATING DEACTIVATING THE SECURITY CODE FROM THE INSIDE 7 LOCK OPERATION WITH TAG KEYS 11 8 LOCK OPERATION WITH KEYPAD AND TAG KEYS 12 8 1 MEMORIZING PERSONAL ACCESS CODES 8 2 DELETING A PERSONAL ACCESS CODE 8 3 DELE...

Страница 3: ...nctions of the same type or unrepairable defects Mottura Serrature di Sicurezza S p A may at its own discretion replace the complete product The warranty on the replaced product will continue until expiration of the original warranty If work is necessary at the customer s home the customer will be required to pay a charge for the costs of transfer of authorized technical person nel Transport will ...

Страница 4: ...BLUELEDsteadyon gridpower GREENLEDsteadyon power batteriesefficient BLUE LED steady on GREEN steady on grid battery power YELLOWLEDsteadyon 3beeps remindertoreplacebatteries YELLOWLEDsteadyon doublehigh lowsound batteriesdrained The reminder to replace the batteries is given before any operation is done opening closing etc You should replace the batteries as soon as possible to ensure correct fun ...

Страница 5: ...ad lets you enter a PIN 3 to 8 digits with which to operate the lock transponder key TAG the escutcheon checks the presence of a transponder key TAG positioned close to the MM logo at the bottom zone B The function keys are number keys to enter codes P Programming to enter the programming phase E Enter to open close the door after entering the code in normal use confirms a selection in programming...

Страница 6: ...e TAG has the transponder inserted in a card in the center In a free TAG system the card is ORANGE In a Protected TAG system the card is YELLOW and shows the number ex M0001 F0001 of the system to which it belongs followed by the key code To prevent the shell from being damaged as a result of continuous opening and closing the key inside the shell should be used ONLY in emergen cies power failure ...

Страница 7: ...the system memory see paragraph 5 6 then re memorize all of the TAGs remaining in your possession see paragraphs 5 1 5 2 accor ding to the required hierarchy master service If a TAG with integrated key is lost or stolen you should replace the cylinder and keys as well If aTAG with duplicates TAG with same code is lost or stolen you have to completely delete all of the TAGs in the system memory see...

Страница 8: ... UP arrow key and then place theTAG that you want to program at master level close to the exter nal escutcheon scanner A multi tone sound from the buzzer confirms that the TAG has been memorized in this phase the LEDs can be ignored because they indicate the status enabled disabled of the service TAGs In case of error the buzzer gives a rapid double high low sound with flashing of the YELLOW LED i...

Страница 9: ...the buzzer sounds about 3 seconds Keep the TAG to be deleted close to the external escutcheon scanner and simultaneously keep E pressed on the internal escutcheon for at least 3 seconds The buzzer will give a long sound to confirm that the TAG has been deleted In case of error it will give an alternating bi tonal sound if the TAG is not in the internal databa se or 5 beeps ONLY in a FREE TAG SYSTE...

Страница 10: ...loses the bolts LATCHBOLTS ONLY When an operation is requested if the lock was closed it opens the bolts if it was open it closes the bolts The spring latch is never operated electronically to open the door you have to operate it manually with the handle This operating mode requires the spring latch handle to be present on both sides of the door Enter programming mode as described in point 4 Press...

Страница 11: ...ide to prevent children or strangers from opening closing the door The code consists of a sequence of 1 to 4 combinations of the UP arrow key and the DOWN arrow key needed to open close the lock instead of the usual enter E key The buzzer gives a long beep to confirm that the security code has been activated To open close the lock from the inside you have to enter the selected code and then press ...

Страница 12: ...reset code Enter programming mode as described in point 4 Press the P key to enter code programming mode Enter a code composed of a minimum of 3 to a maximum of 8 digits then confirm by pressing E The flashing GREEN LED accompanied by 3 high low sounds confirm that the code has been memorized The flashing RED LED accompanied by 2 high low sounds means that the entered code is already in memory The...

Страница 13: ...ans of the internal escutcheon for escutcheon display refer to the appropriate instruction manual provided with the article you can always check the type of power supply and in case of battery power check the charge level In systems with rechargeable batteries disconnect the 230 VAC main power supply to switch off the battery charger and wait AT LEAST 15 seconds before continuing note the BLUE LED...

Страница 14: ...orrect operation of the lock and correct scanning of transponder keys are not guaranteed When the battery charge is no longer sufficient to operate the lock a double high low sound and lighting of theYELLOW LED require their replacement In any case you should replace the batteries once a year Follow these instructions when replacing the batteries Never use rechargeable batteries if your system req...

Страница 15: ...MOTE CONTROL MANUAL N B Do not connect any type of voltage to the cable doing so will permanently damage the lock 13 NOTES ON USING THE SERVICE CYLINDER 14 NOTES ON USING THE MASTER CYLINDER Top position It is designed to overcome power failures or possible malfunctions of the electronic part Therefore it is preferable not to use it in normal operating conditions It must never be used when the loc...

Страница 16: ...gistered Enter the programming menu and register the tran sponder After pressing the E key on the internal escutcheon there is an immediate single low sound The lock is communicating with another device con nected to it on the RS485 communication line The lock is in programming phase Wait for the dialog to end and for the lock to return to stand by then try the operation again Exit programming and...

Страница 17: ...LLOW steady on 3 beeps CHECK TYPE OF POWER GREEN LED RED LED BLUE YELLOW LED BUZZER INTERNAL ESCUTCHEON Fixed BATTERY BLUE steady on MAINS PROGRAMMING GREEN LED RED LED BLUE YELLOW LED BUZZER INTERNAL ESCUTCHEON Fixed Fixed 3 beeps EXTERNAL ESCUTCHEON Fixed Fixed 3 beeps MASTER TAG ACTIVATION GREEN LED RED LED BLUE YELLOW LED BUZZER INTERNAL ESCUTCHEON multi tone sound Activation YELLOW flashing d...

Страница 18: ...activation ACTIVATION OF NUMERICAL KEYPAD CODES GREEN LED RED LED BLUE YELLOW LED BUZZER EXTERNAL ESCUTCHEON Flashing 3 low high sounds memorization Flashing 2 low high sounds code already inserted Flashing 2 low high sounds insertion error DELETION OF NUMERICAL KEYPAD CODES GREEN LED RED LED BLUE YELLOW LED BUZZER EXTERNAL ESCUTCHEON Flashing 3 high low sounds deletion Flashing 2 low high sounds ...

Страница 19: ...19 NOTE ...

Страница 20: ...99286GB 06 14 a_013334 SAFEGUARDINGYOUR SECURITY www mottura it ...

Отзывы: