F04
Range
Default
F04.041
Display Mode2: Measuring characteristics of the display *)
0 - 3
0
0=
Proportional characteristics
Suitable for measurement of rpm, speed and frequency
The display value is proportional to the input frequency "f".
Display =
f (Hz) x
F04.040
F04.039
1=
Reciprocal characteristics, decimal format 999999
Suitable for measurement of baking times, through-put
time and other processing times
The display value is inversely proportional to the
input frequency "f"
Display =
F04.040 x
F04.039
f (Hz)
2=
Reciprocal, clock format 9999 min : 59 sec
**)
otherwise all similar to setting 1
3=
Reciprocal, clock format 99 h : 59 min : 59 sec **)
otherwise all similar to setting 1
F04.042
Set Value2: Preset value to simulate fixed input frequency
-199 999
...
999 999 (x.xx Hz)
0
When you have assigned the function "Set Frequency 2" to any of
the front keys or the control inputs (see parameter group F05),
then this function can be used to temporary substitute the real
input frequency of encoder 2 by a virtual frequency according to
setting. This e.g. allows simulation of the unit and all functions /
outputs while the machine itself is in standstill. When the Set
Value2 is set to 2000 the frequency value corresponds to 20.00
Hz.
*)
Practical setting examples for these display modes can be found in chapter 7.
**)
For setup and scaling of the unit please always use decimal format first and
set your display to full seconds. When you find that all other functions work fine, then
change over to the desired clock format.