SD34002g_e.doc / Sep-13
Page 37 / 60
6.2.5.
Switching Characteristics of Outputs and Preselection Properties
F06
Range
Default
F06.058
Pulse Time 1
0.00 … 9.99
0.00
Output pulse time (sec.) for output K1 (0 = static operation)
F06.059
Pulse Time 2
0.00 … 9.99
0.00
Output pulse time (sec.) for output K2 (0 = static operation)
F06.060
Pulse Time 3
0.00 … 9.99
0.00
Output pulse time (sec.) for output K3 (0 = static operation)
F06.061
Pulse Time 4
0.00 … 9.99
0.00
Output pulse time (sec.) for output K4 (0 = static operation)
F06.062
Switching hysteresis of output K1 (display units) *)
0 … 99999
0
F06.063
Switching hysteresis of output K2 (display units) *)
F06.064
Switching hysteresis of output K3 (display units) *)
F06.065
Switching hysteresis of output K4 (display units) *)
F06.066
Preselection Mode 1
0 … 8
[Actual Value] means:
Absolute speed value.
The unit will not consider
the sign or the direction
but switch both ways
Actual Value means:
Signed speed value.
The unit will consider the
direction and switch only
in one direction according
to the actual sign
0
K1 switching mode
0=
Switches with [Actual Value]
≥
Preset,
No start-up delay. Maintain/latch is possible
1=
Switches with [Actual Value]
≤
Preset
Includes start-up delay. Maintain/latch is possible
2=
Window characteristics:
Switches ON with
Actual Value > [Preset] - Hysteresis
Switches OFF with
Actual Value > [Preset] + Hysteresis
Includes start-up delay. Maintain/latch is possible
3=
Standstill detection
Switches when after frequency = 0 also the
Standstill Time has elapsed.
No start-up delay, no maintain/latch function
4=
Switches with Actual Value
≥
Preset.
No start-up delay, maintain/latch is possible
5=
Switches when Actual Value
≤
Preset
No start-up delay, maintain/latch is possible
6=
Window characteristics:
Switches ON with
Actual Value > [Preset] - Hysteresis
Switches OFF with
Actual Value > [Preset] + Hysteresis
No start-up delay, maintain/latch is possible
7=
Direction of rotation "Forward"
Switches with positive direction (edge A leads B).
Switches OFF upon standstill (frequency = 0 and
standstill time elapsed)
8=
see 7, but "Reverse" (edge B leads A)
F06.067
Preselection Mode 2 (see Preselection Mode 1, but K2)
0 … 8
0
F06.068
Preselection Mode 3 (see Preselection Mode 1, but K3)
F06.069
Preselection Mode 4 (see Preselection Mode 1, but K4)
*) Switching point = Preselection, switch-back point is displaced by the Hysteresis setting