![Motovario EM16-123 F-20 Series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/motovario/em16-123-f-20-series/em16-123-f-20-series_manual_1839482041.webp)
41
Group 13 Inspection & Maintenance Functions
No.
Description
Range
Factory
Setting
unit
Note
13-00
Drive Horsepower Code
----
-
-
*3
13-01
Software Version
----
-
-
*3*4
13-02
Fault Log (Latest 3
Faults)
----
-
-
*3*4
13-03
Accumulated Inverter
Operation Time 1
0~23
-
hour
*3
13-04
Accumulated Inverter
Operation Time 2
0~65535
----
day
*3
13-05
Accumulated Inverter
Operation Time Mode
0: Power On time
1: Operation time
0
-
*3
13-06
Parameter Lock
0: Enable all Functions
1: Preset Speeds from 05-01 to 05-15 Can’t be
Changed
2: All Functions Can’t be Changed Except
for Preset speeds from 05-01 to 05-15
3: Disable All Functions Except 13-06
0
-
13-07
Parameter Lock Code
00000~65535
00000
-
13-08
Reset Drive to Factory
Settings
1150: Reset to factory setting. 50Hz,220V/380V
system.
1160: Reset to factory setting. 60Hz,220V/380V
system.
1250: Reset to factory setting 50Hz,230V/400V
system.
1260: Reset to factory setting 60Hz,230V/460V
system.
1350: Reset to factory setting 50Hz,220V/415V
system.
1360: Reset to factory setting 60Hz,230V/400V
system.
1112: Reset PLC
00000
-