Group 05- Preset Frequency Selections
No.
Description
Range
Factory
Setting
Unit
Note
05-43
Preset Speed13-Acctime
10.0
Sec
*1
05-44
Preset Speed13-Dectime
10.0
Sec
*1
05-45
Preset Speed14-Acctime
10.0
Sec
*1
05-46
Preset Speed14-Dectime
10.0
Sec
*1
05-47
Preset Speed15-Acctime
10.0
Sec
*1
05-48
Preset Speed15-Dectime
10.0
Sec
*1
Group 06- Auto Run Function (Auto Sequencer)
No.
Description
Range
Factory
Setting
Unit
Note
06-00
Auto Run Mode
Selection
(Sequencer)
0: Disabled.
1: Single cycle.
(Continues to run from the Unfinished step if
restarted).
2: Periodic cycle.
(Continues to run from the unfinished step if
restarted).
3: Single cycle, then holds the speed Of final
step to run. (Continues to run from the
unfinished step if restarted).
4: Single cycle.
(Starts a new cycle if restarted).
5: Periodic cycle.
(Starts a new cycle if restarted).
6: Single cycle, then hold the speed of final step
to run. (Starts a new cycle if restarted).
0
-
06-01
Auto _ Run Mode
Frequency Command 1
0.00~599.00
0.00
Hz
*1
06-02
Auto _ Run Mode
Frequency Command 2
0.00
Hz
*1
06-03
Auto _ Run Mode
Frequency Command 3
0.00
Hz
*1
06-04
Auto _ Run Mode
Frequency Command 4
0.00
Hz
*1
06-05
Auto _ Run Mode
Frequency Command 5
0.00
Hz
*1
06-06
Auto _ Run Mode
Frequency Command 6
0.00
Hz
*1
06-07
Auto _ Run Mode
Frequency Command 7
0.00
Hz
*1
06-08
Auto _ Run Mode
Frequency Command 8
0.00
Hz
*1
06-09
Auto _ Run Mode
Frequency Command 9
0.00
Hz
*1
06-10
Auto _ Run Mode
Frequency
Command10
0.00
Hz
*1
06-11
Auto _ Run Mode
Frequency Command
0.00
Hz
*1