8 SETTINGS VIA THE MICT
52
Rev. 07/2013
8.10.4
Miscellaneous – Communication
The two interfaces are currently not yet available.
The CAN and the Modbus interface cannot be activated simultaneously.
CAN
Clicking on the field
CAN enabled
enables or disables the CAN interface on the device.
–
ALL-IN-ONE (J1939)/CANopen
Please select the desired protocol, depending on whether you want to set the
communication for the ALL-IN-ONE or another master control.
–
Baudrate
Select the desired data transfer rate from the list. Using the
ALL-IN-ONE (J1939)
protocol, you
can select between 250 kBit/s and 500 kBit/s. Using the
CANopen
protocol, the baud rate
can be set between 10 kBit/s and 1 MBit/s. For both protocols, the recommended value is
250 kBit/s.
–
Source Addr/CAN Node ID
Using the
ALL-IN-ONE (J1939)
protocol, the source address can be assigned between 0 and
253. Using the
CANopen
protocol, the CANopen node ID can be assigned between 1 and 127.
Please note that IDs cannot be assigned more than once.