7 Wiring and Configuration
Rev. 06/2021
61
Unless you use the CAN bus hybrid cable from MOTORTECH, the CAN and power supply cables to
the CAN bus/NO
X
sensor modules must be routed in parallel.
The power supply cables to the CAN bus/NO
X
sensor modules should have a minimum cross-
section of 1.5 mm
2
. Depending on the total wire length of both power supply cables and the num-
ber of CAN bus/NO
X
sensor modules connected, provide sufficient supply voltage to the
EasyNO
ₓ
. Possible cable cross-sections and total cable lengths depending on the supply voltage
can be found in the following tables.
Cable cross section 1.5 mm
2
Total cable length
Minimum supply voltage
1 module
2 modules
25 m (82')
18 V DC
20 V DC
50 m (164')
20 V DC
24 V DC
Cable cross section 2.5 mm
2
Total cable length
Minimum supply voltage
1 module
2 modules
25 m (82')
17.3 V DC
18.5 V DC
50 m (164')
18.5 V DC
21 V DC
Insert the supplied sealing inserts and sealing insert pins into the cable glands through which
you do not feed any cables. Close all cable glands with a tightening torque of 8 Nm (5.9 lb-ft).
Unless you want to exchange the memory card as well, close the door of the EasyNO
ₓ
housing
after wiring the EasyNO
ₓ
and turn the locks of the door to the closed position (see section
Opening and Closing of Housing
on page 58).
Содержание EasyNOx
Страница 1: ...EasyNOX NOX Monitoring Operating Manual P N 01 50 026 EN Rev 06 2021 ...
Страница 33: ...4 Product Description Rev 06 2021 33 4 1 7 Overview Drawings 4 1 7 1 Dimensions EasyNOX ...
Страница 34: ...4 Product Description 34 Rev 06 2021 ...
Страница 35: ...4 Product Description Rev 06 2021 35 CAN Bus NOX Sensor Module P N 63 05 015 ...
Страница 36: ...4 Product Description 36 Rev 06 2021 I O Communication Module Optional ...
Страница 142: ......