Control Interface
5 - 3
Transactions
I
2
C transactions control the SE3300, where a transaction consists of a command followed by a response. I
2
C
is a master/slave protocol, meaning the host initiates both transmissions.
The SE3300 typically processes a command in less than 1 ms, but some commands take up to 100 ms. For
this reason, after sending a command, the host (I
2
C master) should request a response, and if the SE3300
does not respond the host should retry the response request for up to 100 ms. If the SE3300 does not respond
within this time, a hard failure occurred.
The I
2
C format of these commands and responses is as follows.
I
2
C Command Format
<I2C-Start Bit> <SLA-W> <Cmd-Opcode> <[SE3300-Cmd-Data]> <Checksum> <I2C-Stop-Bit>
where:
•
I2C-Start-Bit
and
I2C-Stop-Bit
are as defined by the I
2
C specification
•
SLA-W
is 0xB8 (Slave-Addr + Write-Op) or
•
Slave Address is 0x5C (or 0xB8 after shifting into 7 MSBs)
•
Write-Op is 0x00
•
Opcode
is 1 byte from the
SE3300 Command Op
column in
.
•
[SE3300-Cmd-Data]
is from the
SE3300 Command Data
column in
. This can be
NULL.
•
Checksum
is a 1 byte checksum of the
SE3300 Cmd Data
I
2
C Response Format
<I2C-Start Bit> <SLA-R> <Rsp-Opcode> <Status> <[SE3300-Rsp-Data]> <I2C-Stop-Bit>
Where:
•
I2C-Start-Bit
and
I2C-Stop-Bit
are as defined by the I
2
C specification
•
SLA-R
is 0xB9 (Slave-Addr + Read-Op) or
•
Slave Address is 0x5C (or 0xB8 after shifting into 7 msb's)
•
Read-Op is 0x01
•
Opcode
is 1 byte from the
SE3300 Response Op
•
Status
indicates whether the SE3300 successfully processed the command. See
•
[SE3300-Rsp-Data]
is from the
SE3300 Response Data
column in
. This can be
NULL.
Содержание SE3300
Страница 1: ...SE3300 INTEGRATION GUIDE ...
Страница 2: ......
Страница 3: ...SE3300 INTEGRATION GUIDE 72E 148589 01 Revision 8 September 2011 ...
Страница 6: ...iv SE3300 Integration Guide ...
Страница 10: ...viii SE3300 Integration Guide ...
Страница 14: ...xii SE3300 Integration Guide ...
Страница 18: ...1 4 SE3300 Integration Guide ...
Страница 26: ...2 8 SE3300 Integration Guide Figure 2 3 SE3300 Illumination and Aiming Path See Table 2 5 See Table 2 5 ...
Страница 38: ...3 10 SE3300 Integration Guide ...
Страница 41: ...Electrical Interface 4 3 Figure 4 2 21 Pin ZIF Connector SE3300 Imager to Flex Kyocera 6283 Series continued ...
Страница 42: ...4 4 SE3300 Integration Guide Figure 4 3 21 Pin ZIF Connector PL3307 Decoder to Flex Molex 54809 Series ...
Страница 43: ...Electrical Interface 4 5 Figure 4 4 21 Pin ZIF Connector PL3307 Decoder to Flex Molex 54809 Series continued ...
Страница 44: ...4 6 SE3300 Integration Guide Figure 4 5 SE3300 to PL33XX Decoder 21 Pin Flex ...
Страница 58: ...5 14 SE3300 Integration Guide ...
Страница 68: ...6 10 SE3300 Integration Guide ...
Страница 70: ...A 2 SE3300 Integration Guide ...
Страница 72: ......
Страница 73: ......