Installation Instructions
http://www.motorola.com/computer/literature
1-23
1
IP Installation on the MVME172P4
The MVME172P4 accommodates up to four IndustryPack (IP) modules.
Install the IP modules on the MVME172P4 as follows:
1. Each IP module has two 50-pin connectors that plug into two
corresponding 50-pin connectors on the MVME172P4: J4/J5,
J10/J11, J20/J21, J29/J30. See Figure 2-1 for the MVME172P4
connector locations.
– Orient the IP module(s) so that the tapered connector shells mate
properly. Plug IP_a into connectors J4 and J5; plug IP_b into J10
and J11. Plug IP_c into J20 and J21; plug IP_d into J29 and J30.
If a double-sized IP is used, plug IP_ab into J4, J5, J10, and J11;
plug IP_cd into J20, J21, J29, and J30.
2. Four additional 50-pin connectors (J7, J8, J26, and J27) are
provided behind the MVME172P4 front panel for external cabling
connections to the IP modules. There is a one-to-one
correspondence between the signals on the cabling connectors and
the signals on the associated IP connectors (i.e., J8 has the same
IP_a signals as J4; J7 has the same IP_b signals as J10; J27 has the
same IP_c signals as J20; and J26 has the same IP_d signals as J29).
– Connect user-supplied 50-pin cables to J7, J8, J26, and J27 as
needed. (Because of the varying requirements for each different
kind of IP, Motorola does not supply these cables.)
– Bring the IP cables out the narrow slots in the MVME172P4
front panel and attach them to the appropriate external
equipment, depending on the nature of the particular IP(s).
MVME172P4 Installation
With EPROM, SIM, and IP modules installed and headers or switches
properly configured, proceed as follows to install the MVME172P4 in a
VME chassis:
1. Turn all equipment power OFF and disconnect the power cable
from the AC power source.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com