Web Page Reference
96
The software image will now be uploaded to the unit. This upload should only take a few seconds.
Once complete the image is verified and validated to ensure that no errors occurred during transfer
and that the image is valid to run on the current platform. If there are any problems a warning
screen will appear.
The unit being upgraded will now display information about the build it currently has stored in
the image bank and the one that’s just been uploaded. If the image is not the right one, the user
has the option to go back and reload a new image. (See
Figure 55
Software Upgrade Image Check
The user should ensure that the correct image is shown before pressing the “Program Software
Image into Non-Volatile Memory” button. Once this button has been pressed the image is stored
into non-volatile memory, this process can take up to 60 seconds and must not be interrupted.
If the upgrade process is interrupted during the erasure of the image bank, or during the repro-
gramming of the image bank, the image bank will be left in a corrupt state. If this occurs the
software must be reloaded. All software images that are stored in non-volatile memory are pro-
tected via the use of CRCs. If the software detects an invalid CRC the image bank is marked as
‘corrupt’ and the 500 Series bridge boot code will boot the fixed software image. If this occurs the
user must attempt to reload the correct version of software.
During the write process the progress of the upgrade is displayed on the progress tracking page
(
). The upgrade process should not be interrupted. Interruption of this process can
result in a corrupt main software image, which will result in the recovery image been booted at
the next reset cycle.
Содержание MOTOWI 4
Страница 1: ...PTP 500 Series User Guide phn 1115 000v001 ...
Страница 74: ...Web Page Reference 74 Figure 37 Save Configuration File Screen ...
Страница 100: ...Web Page Reference 100 Figure 59 Spectrum Management as seen from the Master ...
Страница 108: ...Web Page Reference 108 Figure 66 Spectrum Management Master Screen With Operational Restrictions ...
Страница 112: ...Web Page Reference 112 Figure 68 Remote Management ...
Страница 165: ...Data Rate Calculations 165 Figure 112 QPSK 0 50 Single Payload Figure 113 QPSK 0 75 Single Payload ...
Страница 166: ...Data Rate Calculations 166 Figure 114 16 QAM 0 50 Single Payload Figure 115 16 QAM 0 75 Single Payload ...
Страница 167: ...Data Rate Calculations 167 Figure 116 64 QAM 0 67 Single Payload Figure 117 64 QAM 0 83 Single Payload ...
Страница 168: ...Data Rate Calculations 168 Figure 118 256 QAM 0 75 Single Payload Figure 119 QPSK 0 50 Dual Payload ...
Страница 169: ...Data Rate Calculations 169 Figure 120 QPSK 0 75 Dual Payload Figure 121 16 QAM 0 50 Dual Payload ...
Страница 170: ...Data Rate Calculations 170 Figure 122 16 QAM 0 75 Dual Payload Figure 123 64 QAM 0 67 Dual Payload ...
Страница 171: ...Data Rate Calculations 171 Figure 124 64 QAM 0 83 Dual Payload Figure 125 256 QAM 0 75 Dual Payload ...
Страница 197: ...Glossary 197 UTP Unshielded Twisted Pair VLAN Virtual Local Area Network ...