Web Page Reference
115
SNMP Community String:
The SNMP community string acts like a password between the
networks SNMP management entity and the distributed SNMP clients (600 Series bridge). Only
if the community string is configured correctly on all SNMP entities can the flow of management
information take place. By convention the default value is set to ‘public’. When the community
string is changed the system requires a mandatory reboot before the new string or phrase is
adopted.
SNMP Port Number:
Is the port the SNMP management agent is listening to for commands
from an SNMP manager. The default value for this port number is 161.
SNMP Trap IP Address:
Is the address of either the network SNMP manager or Trap receiver.
When asynchronous events (traps in SNMP terminology) are generated, the client unicasts these
to this IP Address. When the address is changed the system requires a mandatory reboot before
the setting is adopted
SNMP Trap Port Number:
The SNMP Trap Port Number is the port number of either the
networked SNMP manager or Trap receiver. By convention the default value for the port number
is 162. When the port number is changed the system requires a mandatory reboot before the
setting is adopted.
WiMAX Control:
Enables and Disables the WiMAX (802.16) MIB. This control is only displayed
when ‘Fixed Frequency’ is selected during installation.
8.3.10.7
SMTP (Simple Mail Transport Protocol)
The SMTP client is an alternative method for the 500 Series bridge to alert a system administrator
when there are or have been system errors SMTP
Email Alert:
This attribute controls the activation of the SMTP client.
SMTP Enabled Messages:
The SMTP Enabled Messages attribute controls which email alerts
the unit will send.
SMTP IP Address:
The IP address of the networked SMTP server.
SMTP Port Number:
The SMTP Port Number is the port number used by the networked
SMTP server:
By convention the default value for the port number is 25.
SMTP Source Email Address:
The email address used by the 500 Series to log into the SMTP
server. This must be a valid email address that will be accepted by your SMTP Server.
SMTP Destination Email Address:
The email address to which the 500 Series bridge will send
the alert messages.
8.3.10.8
SNTP (Simple Network Time Protocol)
The SNTP client allows the 500 Series to obtain accurate date and time updates from a networked
timeserver. The system time is used for SNMP and event logging.
SNTP State:
When enabled, the Remote Management web page permits the following attributes
to be set.
Содержание MOTOWI 4
Страница 1: ...PTP 500 Series User Guide phn 1115 000v001 ...
Страница 74: ...Web Page Reference 74 Figure 37 Save Configuration File Screen ...
Страница 100: ...Web Page Reference 100 Figure 59 Spectrum Management as seen from the Master ...
Страница 108: ...Web Page Reference 108 Figure 66 Spectrum Management Master Screen With Operational Restrictions ...
Страница 112: ...Web Page Reference 112 Figure 68 Remote Management ...
Страница 165: ...Data Rate Calculations 165 Figure 112 QPSK 0 50 Single Payload Figure 113 QPSK 0 75 Single Payload ...
Страница 166: ...Data Rate Calculations 166 Figure 114 16 QAM 0 50 Single Payload Figure 115 16 QAM 0 75 Single Payload ...
Страница 167: ...Data Rate Calculations 167 Figure 116 64 QAM 0 67 Single Payload Figure 117 64 QAM 0 83 Single Payload ...
Страница 168: ...Data Rate Calculations 168 Figure 118 256 QAM 0 75 Single Payload Figure 119 QPSK 0 50 Dual Payload ...
Страница 169: ...Data Rate Calculations 169 Figure 120 QPSK 0 75 Dual Payload Figure 121 16 QAM 0 50 Dual Payload ...
Страница 170: ...Data Rate Calculations 170 Figure 122 16 QAM 0 75 Dual Payload Figure 123 64 QAM 0 67 Dual Payload ...
Страница 171: ...Data Rate Calculations 171 Figure 124 64 QAM 0 83 Dual Payload Figure 125 256 QAM 0 75 Dual Payload ...
Страница 197: ...Glossary 197 UTP Unshielded Twisted Pair VLAN Virtual Local Area Network ...