Fault Finding
133
Differentiating between 1-3 and 4 can be achieved by removing the power for 1 second. Watch
the Ethernet indicator for 1 minute while power is removed, if it never flashes then the problem is
1-3. Take the jumper (J905) out of the PIDU Plus and check the current taken by the ODU. This
should be 300mA to 1A when starting to run normally.
If the Ethernet indicator flashes to begin with but then stops flashing, the ODU is powered and
software loaded but Ethernet connectivity has been lost between the ODU and the users connected
equipment. All Ethernet connections should be rechecked.
Power Indoor Unit LED check chart:
Mode
Green LED
Yellow LED No Ethernet
Cable Connected
Yellow LED Ethernet
Cable Connected
between PIDU Plus and
NIC/Switch/Hub
No Power Applied
Off
Off
Off
Power Applied
On
Will flash once per
second regularly
approximately 30 seconds
after power applied for
10 seconds then will go
out and stay out
Will flash once per
second regularly
approximately 30 seconds
after power applied for
10 seconds then operate
as Ethernet
Link/Activity LED
Valid Ethernet Link and
no traffic
On
N/A
Will be on solid for a
valid link.
Valid Ethernet Link with
traffic
On
N/A
Will be on solid, but will
blink randomly as traffic
passes through.
Recovery Switch Pressed
and held for greater than
10 seconds from power on
(Recovery is pressed
while power is applied)
On
Off while switch pressed. Approximately 30 seconds
after releasing the switch, flashes twice per second
regularly for 10 seconds, then boots in “Recovery
Mode” While in “Recovery Mode” the unit will only
be accessible via the IP address 10.10.10.10 or
169.254.1.1.
10.1.3
Checking your wiring
If the above procedures fail to diagnose the issue you may have a wiring fault. Unplug the RJ45
from the PIDU+ and check the following resistances at the RJ45:
1. Check the cable resistance between pins 1 & 2, 3 & 6, 4 & 5 and 7 & 8 at the RJ45.
2. Check against column 2 in
. Resistances for each pair should be within 1 ohm of each
other.
Содержание MOTOWI 4
Страница 1: ...PTP 500 Series User Guide phn 1115 000v001 ...
Страница 74: ...Web Page Reference 74 Figure 37 Save Configuration File Screen ...
Страница 100: ...Web Page Reference 100 Figure 59 Spectrum Management as seen from the Master ...
Страница 108: ...Web Page Reference 108 Figure 66 Spectrum Management Master Screen With Operational Restrictions ...
Страница 112: ...Web Page Reference 112 Figure 68 Remote Management ...
Страница 165: ...Data Rate Calculations 165 Figure 112 QPSK 0 50 Single Payload Figure 113 QPSK 0 75 Single Payload ...
Страница 166: ...Data Rate Calculations 166 Figure 114 16 QAM 0 50 Single Payload Figure 115 16 QAM 0 75 Single Payload ...
Страница 167: ...Data Rate Calculations 167 Figure 116 64 QAM 0 67 Single Payload Figure 117 64 QAM 0 83 Single Payload ...
Страница 168: ...Data Rate Calculations 168 Figure 118 256 QAM 0 75 Single Payload Figure 119 QPSK 0 50 Dual Payload ...
Страница 169: ...Data Rate Calculations 169 Figure 120 QPSK 0 75 Dual Payload Figure 121 16 QAM 0 50 Dual Payload ...
Страница 170: ...Data Rate Calculations 170 Figure 122 16 QAM 0 75 Dual Payload Figure 123 64 QAM 0 67 Dual Payload ...
Страница 171: ...Data Rate Calculations 171 Figure 124 64 QAM 0 83 Dual Payload Figure 125 256 QAM 0 75 Dual Payload ...
Страница 197: ...Glossary 197 UTP Unshielded Twisted Pair VLAN Virtual Local Area Network ...