Testing the battery backup
31st Oct 01
Installation & Configuration: Horizon
macro outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
Inst. 7–19
Testing the battery backup
Overview of
battery backup
test
Objective
The battery backup test verifies whether or not the battery backup is operating
correctly.
Test equipment
The battery backup test does not require any test equipment.
Commands
The battery backup test does not require any software commands.
Battery backup
test procedures
The test procedure carried out will depend on battery backup configuration.
NOTE
If the BTS cabinet is operational or otherwise visible to the
OMC-R, alarms will be generated. Notify the OMC-R
before carrying out these test procedures.
The internal or external batteries must be fully charged
before carrying out these test procedures.
The battery capacity test discharges the internal batteries
to –44 V dc. If an external power supply failure occurs
immediately after the test, the battery back up duration is
reduced to approximately 3 minutes. The internal batteries
recharge to approximately 80 % capacity in less than one
hour.
Internal battery backup
To test operation of internal battery backup:
1.
Operate the CAB front panel BATTERY TEST button to initiate internal
battery capacity test.
2.
Check that the BATTERY CAPACITY LEDs flash during the test.
3.
Check the 15 mins battery capacity LED is illuminated at the end of the
test.
The test of internal battery backup operation is now complete.
Содержание Horizonmacro outdoor
Страница 126: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 128: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 140: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 142: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 160: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 162: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 178: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 180: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 206: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 208: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...