PIX inputs and
outputs
PIX outputs
PIX outputs comprise four relay contacts controlled by the alarm board and
MCUF. The relays have multiple contacts, some normally open and some
normally closed. The contacts are rated for 1 A at 30 V. The contacts may be
used for control of external equipment such as fans or audible alarms.
PIX inputs
PIX inputs comprise 16 connections to external sensors. These inputs report
alarms to the BSC, via the alarm board and MCUF, which forwards the alarms to
the OMC-R. The end-user supplies the external sensors. Each sensor connects
across an opto-coupled pair of PIX inputs (eight per PIX connector).
All sensors must be dry-contact type with the following specification:
5 kohms or greater across sense inputs for logic 1 (PIX opto-coupler off).
500 ohms or less across sense inputs for logic 0 (PIX opto-coupler on).
Table 3-11 shows PIX0 connections and Table 3-12 shows PIX1 connections.
Table 3-11 PIX0 pin connections (37-way D-type)
Pin
no.
Signal/Description
Pin
no.
Signal/Description
1
Site input Ext 1–1
19
Not connected
2
Site input Ext 2–1
20
Site input Ext 1–2
3
Site input Ext 3–1
21
Site input Ext 2–2
4
Site input Ext 4–1
22
Site input Ext 3–2
5
Site input Ext 5–1
23
Site input Ext 4–2
6
Site input Ext 6–1
24
Site input Ext 5–2
7
Site input Ext 7–1
25
Site input Ext 6–2
8
Site input Ext 8–1
26
Site input Ext 7–2
9
Not connected
27
Site input Ext 8–2
10
Not connected
28
spare
11
Site output relay 1 – NO
29
Site output relay 1 – NC
12
Site output relay 2 – NO
30
Site output relay 1 – COM
13
Site output relay 2 – NC
31
Site output relay 2 – COM
14
Site output relay 3 – NO
32
Site output relay 3 – NC
15
Site output relay 4 – NO
33
Site output relay 3 – COM
16
Site output relay 4 – NC
34
Site output relay 4 – COM
17
Not connected
35
Not connected
18
Not connected
36
Not connected
Содержание Horizonmacro outdoor
Страница 126: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 128: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 140: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 142: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 160: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 162: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 178: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 180: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 206: ...GSM 204 423 31st Oct 01 ii Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...
Страница 208: ...GSM 204 423 31st Oct 01 iv Installation Configuration Horizonmacro outdoor CONTROLLED INTRODUCTION 68P02902W03 A ...