Issue 1.1 April 2006
Page 44
7.7.9 Mounting The Canopy 150/300 PIDU
This step is optional. Motorola recommends that you mount the 150/300 PIDU on a wall or
other suitable mounting surface. This prevents the unit from being knocked or kicked and can
help maintain link availability. Ensure that the reset switch can be accessed when mounting
the unit.
Step 1: Fix the 150/300 PIDU to the wall using the lugs provided.
Step 2: Make connections as per Section 7.7.7.
WARNING
The 150/300 PIDU is not waterproof and should be mounted away from sources
of moisture. If mounted outdoors the 150/300 PIDU should be mounted in a rain proof
enclosure, preferably ventilated.
It is also recommended that you fit a drip loop on the 150/300 PIDU to ODU cable to ensure
that any moisture that runs down the cable into the cabinet or enclosure cannot enter the
150/300 PIDU. As shown in Figure 18 the network connection and mains cable should be
treated in the same way if there is a risk that they can carry moisture to the 150/300 PIDU.
Содержание Canopy 150 Mbps Backhaul
Страница 1: ...Canopy 150 300 Mbps Backhaul User Guide BH150 300 UG en Issue 1 1 April 2006 ...
Страница 25: ...Issue 1 1 April 2006 Page 24 Figure 5 Canopy 150 300 PIDU Power Input ...
Страница 66: ...Issue 1 1 April 2006 Page 65 Figure 29 Save and Restore Configuration Page Figure 30 Save File Pop up ...
Страница 97: ...Issue 1 1 April 2006 Page 96 Figure 59 Spectrum Management Help Page ...
Страница 162: ...Issue 1 1 April 2006 Page 161 Figure A8 Surge Arrestor ALPU ORT Connection Illustration ...
Страница 167: ...Issue 1 1 April 2006 Page 166 Figure 113 64 QAM 0 92 Dual Payload Figure 114 256 QAM 0 81 Dual Payload ...