Issue 1.1 April 2006
Page 42
Should it be necessary to disconnect the 150/300 PIDU to ODU cable at the ODU this can be
achieved by removing the weather proofing gland and depressing the RJ45 locking tab with a
small screwdriver as shown below:
Figure 16: Disconnecting the ODU
Warning
: Ensure that power is removed from the system at the 150/300 PIDU to prevent
damage to the ODU whilst making or breaking the connection.
7.7.4 Routing the Cable
After connecting the cable to the ODU it can be routed and secured using standard cable
routing and securing techniques. When the cable is in place it can then be cut to the desired
length at the 150/300 PIDU prior to connection to the 150/300 PIDU.
7.7.5 Fitting A Surge Arrestor
If you have opted to fit a Surge Arrestor, this should be installed by following the
manufacturers’ instruction. For recommended types see Section 12 “Lightning Protection”
7.7.6 Grounding The Installation
The Canopy 150/300 Mb BH Outdoor unit must be properly grounded to protect against
power surges. It is the user’s responsibility to install the equipment in accordance with
Section 810 of the National Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the
Canadian Electrical Code or the National Electrical Code in the country of installation. These
codes describe correct installation procedures for grounding the outdoor unit, mast, lead-in
wire and discharge unit, size of grounding conductors and connection requirements for
grounding electrodes. It is recommended that installation of the outdoor unit be contracted to
a professional installer. See Section 12 “Lightning Protection” for recommended grounding
kits.
7.7.7 Making the ODU Connection At The Canopy 150/300 PIDU
The ODU is connected to the 150/300 PIDU by means of a concealed RJ45 connector. The
RJ45 connection has been placed inside the 150/300 PIDU hinged cover to prevent the user
inadvertently plugging other equipment into the ODU RJ45 socket.
Warning:
Plugging other equipment into the ODU RJ45 socket may damage the equipment
due to the non-standard techniques employed to inject DC power into the 1000BaseT
Содержание Canopy 150 Mbps Backhaul
Страница 1: ...Canopy 150 300 Mbps Backhaul User Guide BH150 300 UG en Issue 1 1 April 2006 ...
Страница 25: ...Issue 1 1 April 2006 Page 24 Figure 5 Canopy 150 300 PIDU Power Input ...
Страница 66: ...Issue 1 1 April 2006 Page 65 Figure 29 Save and Restore Configuration Page Figure 30 Save File Pop up ...
Страница 97: ...Issue 1 1 April 2006 Page 96 Figure 59 Spectrum Management Help Page ...
Страница 162: ...Issue 1 1 April 2006 Page 161 Figure A8 Surge Arrestor ALPU ORT Connection Illustration ...
Страница 167: ...Issue 1 1 April 2006 Page 166 Figure 113 64 QAM 0 92 Dual Payload Figure 114 256 QAM 0 81 Dual Payload ...