11.6 Environmental Specifications
Category Specification
Temperature
ODU: -40°F (-40°C) to 140°F (+60°C)
150/300 Mbps Backhaul PIDU (SPIDU): 32°F (0°C) to
140°C)
150/300 Mbps Backhaul PIDU: -40°F (-40°C) to 140°F
(+60°C)
Wind Loading
151mph Max (242kph). See section 13 “Wind Loading” for a
full description.
Humidity
100% Condensing
Waterproof
IP65 (ODU), IP53 (150/300 Mbps Backhaul PIDU)
UV Exposure
10 year operational life (UL746C test evidence)
Standard Channel Raster (low channel set to 5742MHz), Channels 0/9 are limited to operate at 21dBm Max
Low Channel set to 5740MHz, Channel 0 is limited to operate at 17dBm Max, Channel 9 at 21dBm Max
Low Channel set to 5744MHz, Channel 0 is limited to operate at 21dBm Max, Channel 9 at 17dBm Max
Low Channel set to 5746/8MHz, Channel 0 is limited to operate at 21dBm Max, Channel 9 is not allowed