64
5
ELECTRICAL SYSTEM
5.3. Trip function (TD)
This function describes the correct working/visualiza-
tion of the board automatic partial totalizer.
This function is always represented on digit 13÷16
and by logo TD (pic.5-4).
The visualized data represents the vehicle covered
distance expressed in miles or km (depending on
the selected measurement unit), with resolution 0.1
(miles or km).
This counter is automatic: in fact it automatically
starts with the fi rst pulse arriving from speed sensor.
The data isn’t memorized in a permanent mode.
It is possible setting the counter of this parameter to zero
by pushing the
Set
button for about 03 sec. (in correspon-
dence of the TD function) till the value 000.0 appears.
It is possible setting to zero the TD function both when the
vehicle is stopped and when it is running, this causes also
the setting to zero of LAP and AVE functions.
If the data gets over 999.9 the system automatically sets
to zero TD, LAP and AVE functions and then starts again
the counting.
Obs.5-1:
So: If there is no feeding the TD value is
hopeless lost.
5.4. Time Function (TIME)
This function describes the correct working/visualization
of the current hour. This function is always shown in the
format hh:mm, by using digit 1÷4 (pic.5-5).
Clock is active also when the microcontroller is in sleep
mode phase and regulation of the hour can be done only
when the vehicle
is stopped
.
This information is not saved in the memory.
Visualized Series:
from 0:00 to 23:59 for method 0-24
from 0:00 to 12:59 for method 0-12 am
from 1:00 to 11:59 for method 0-12 pm
Clock precision: ±2.5 sec/day
Obs. 5-2:
If there is no feeding the TIME value is ho-
peless lost.
Picture 5-4: Partial covered distance
Picture 5-5: clock