background image

 

 

WHITEHALL MANUFACTURING

 

 P.O. BOX 3527 

 City of Industry, CA 91744-0527 U.S.A. 

Phone (800) 782-7706 

 (626) 968-6681 

 Fax (626) 855-4862 

 www.whitehallmfg.com 

10 

Description 

Used on 
Models 

Instructions 

 

TTS1 

 

Tank Top Seat 
for 508 mm (20 
inch) wide tubs 

H-60-S 
H-75-S 
H-90-S 
S-85-S 
S-85-SL 

1. 

Loosen wing nuts on the lower 
mounting clip assemblies  

2. 

Position tank top seat assembly 
over radius of tank and align hooks 
with tank rim 

3. 

Push up on the lower mounting clip 
assemblies and tighten wing nuts 
to clamp seat to the Whirlpool rim  

4. 

For maintenance, see the 

Error! R

eference source not found.

 

section.   

 

 

TTS2 

 

Tank Top Seat 
for 610 mm (24 
inch) wide tubs 

H-105-S 
S-90-S 
S-90-SL 
S-110-S 
S-110-SL 
L-75-S 
L-90-S 
L-105-S 
L-105-SL

 

ARS 

 

Arm Rest 
Support 

All 

Hang support on edge of tank as 
shown.  For maintenance, see the 

Disinfecting and Cleaning 
Instructions

 section.   

 

AS1 

 

Adjustable 
Suspension 
Seat for 508 
mm (20 inch) 
wide tubs 

H-60-S 
H-75-S 
H-90-S 
S-85-S 
S-85-SL 

Hang seat supports on sides of 
tub.  Hang seat on seat supports.  
Adjust height of seat as desired. 
For maintenance, see the 

Disinfecting and Cleaning 
Instructions

 section.

  

 

AS2 

 

Adjustable 
Suspension 
Seat for 610 
mm (24 inch) 
wide tubs, 
except Lo-Boy 

H-105-S 
S-90-S 
S-90-SL 
S-110-S 
S-110-SL 

AS3 

 

Adjustable 
Suspension 
Seat for Lo-
Boy 

L-75-S 
L-90-S 
L-105-S 
L-105-SL 

 

 

 

 

Содержание Whitehall Extremity E-15-S

Страница 1: ...ty E 15 S E 22 S E 22 SP E 27 S E 45 S Hi Boy H 60 S H 75 S H 90 S H 105 S Lo Boy L 75 S L 90 S L 105 S L 105 SL Sports S 85 S S 85 SL S 90 S S 90 SL S 110 S S 110 SL Slant Back SB 100 S P O Box 3527 City of Industry CA 91744 0527 U S A 800 782 7706 626 968 6681 www whitehallmfg com S 110 SL E 27 S E 22 SP ...

Страница 2: ...l Manufacturing a division of Acorn Engineering and a member of Morris Group International Any reproduction dissemination or distribution of this document in whole or in part without prior written authorization of Whitehall Manufacturing is strictly prohibited While every effort has been made to ensure the accuracy of information provided in this document please note the information is subject to ...

Страница 3: ... Intended Use 7 Contraindications 7 User Skills 7 Device Description 8 Options and Accessories 9 Facility Requirements 11 Instructions 14 Installation Instructions 14 Operating Instructions 16 Draining Instructions 17 Thermometer Calibration Instructions 19 Disinfecting and Cleaning Instructions 20 Turbine Maintenance 22 Troubleshooting 22 Classification 23 Specifications 23 ...

Страница 4: ...to drop off the waste equipment for recycling contact your local waste collection authority General Warning or Caution Indicates personal injury or damage to the equipment is possible Electric Shock Indicates a hazard arising from dangerous voltage Any mishandling could result in irreparable damage to the equipment and or personal injury or death Refer To Manual Instructions for Use Indicates that...

Страница 5: ...n improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally Use of accessories and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation Use o...

Страница 6: ...ient To avoid the risk of electric shock this equipment must only be connected to a supply mains with protective earth Connect the power cord to a Ground Fault Circuit Interrupter GFCI medical grade receptacle No parts of the Whirlpool including the power supply cord are repairable or replaceable by service personnel No modification of the Whirlpool is allowed To protect stainless steel surfaces u...

Страница 7: ...in which hydrotherapy is contraindicated Active infection anywhere in the body Open wounds Loss of temperature sensation Hydrophobia Heat or cold intolerance Poor balance Kidney failure Safety Effectiveness has not been established in patients With Cancer Caution is advised when treating patients with cancer It is best to work with the consent of a physician Who Hemorrhage Caution is advised when ...

Страница 8: ...ined by opening the drain valve to a fixed drain For SL models water is drained by either redirecting the water flow to the drain hose on the turbine and then to a sink by turning on the optional separate drain pump SDP and then draining to a sink or floor drain or by opening up the drain valve under the tub to the floor after which the water will flow to a nearby floor drain The interior of the t...

Страница 9: ...ly All S models SDP Separate Drain Pump All SL models GFI Ground Fault Circuit Interruption Cable All EGXX where XX indicates the color of the powder coat Powder Coat Paint All except Slant Back LOGO Logo selected by customer All except Slant Back The following accessories are available Description Used on Models Instructions RS Reclining Seat L 75 S L 90 S L 105 S L 105 SL Hang seat on back edge ...

Страница 10: ... Error R eference source not found section TTS2 Tank Top Seat for 610 mm 24 inch wide tubs H 105 S S 90 S S 90 SL S 110 S S 110 SL L 75 S L 90 S L 105 S L 105 SL ARS Arm Rest Support All Hang support on edge of tank as shown For maintenance see the Disinfecting and Cleaning Instructions section AS1 Adjustable Suspension Seat for 508 mm 20 inch wide tubs H 60 S H 75 S H 90 S S 85 S S 85 SL Hang sea...

Страница 11: ...eptacle installed by licensed electrician Ability to install floor anchors S and SP models only Environmental conditions within those specified in the Specification section of this manual NOTE The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals CISPR 11 class A If it is used in a residential environment for which CISPR 11 class B is normally r...

Страница 12: ...ow for L W D OH CW and CD values Mains input medical grade GFCI Filler inlet assembly Optional thermostatic mixing valve 51 mm 2 inch Drain 51 mm 2 inch outer diameter x 127 mm 5 inch long drain tube coupling Mounting clip assembly 51 mm 2 inch standard drain and overflow assembly Customer provided Key L Length W Width D Depth OH Overall Height CD Center of Drain to Wall 305 mm 12 in REC MIN 279 m...

Страница 13: ...7 18 610 24 E 22 SP 864 34 E 27 S 533 21 686 27 E 45 S 813 32 635 25 787 31 H 60 S 914 36 508 20 711 28 864 34 737 29 H 75 S 1067 42 H 90 S 1219 48 H 105 S 610 24 787 31 L 75 S 1321 52 457 18 610 24 L 90 S 1524 60 L 105 S 1676 66 L 105 SL 699 27 5 N A S 85 S 1219 48 508 20 635 25 787 31 737 29 S 85 SL 889 35 N A S 90 S 1168 46 610 24 878 31 787 31 S 90 SL 889 35 N A S 110 S 1422 56 787 31 787 31 S...

Страница 14: ...tep c f Remove and set aside attaching hardware from mounting clip assemblies g Attach brackets to floor using 6 35 mm 1 4 inch bolts aligning the brackets so they are just inward from and parallel to the line drawn in step b to allow for the sheet metal thickness of the tub skirt h Lift the tub over the brackets and attach with the bolts and washers using a Phillips screwdriver i Attach filler in...

Страница 15: ... Figure 4 Place discharge nozzle 5 into storage socket 6 For SL SDP models only water will flow through hose if discharge nozzle 5 is lower than water level 3 Turn the pressure control valve handle 11 fully clockwise then fully counterclockwise to completely lubricate the plunger assembly 4 For SL SDP models only Figure 4 Insert electrical cord twist lock plug 7 into socket 9 and turn clockwise a ...

Страница 16: ...alve handle 11 fully clockwise This will generate maximum water circulation 4 Turn the turbine power switch 13 on 5 Adjust position of turbine by slowly pushing down on and rotating the top of the motor support casting 14 until the bottom of the turbine 12 is at the desired location Tighten handle 5 to lock in place 6 Adjust pressure control valve handle 11 to change level of water circulation 7 T...

Страница 17: ...s diverts water to the hose 1 d Place and hold discharge nozzle 5 into sink then turn the turbine power switch 4 on to start draining to sink e When water stops discharging from the nozzle turn the turbine power switch 4 off f Drain remaining water using drain valve 2 or by using a dry sponge 3 S and SP models with a Standard drain and overflow Figure 8 and Figure 9 Lift combination drain and over...

Страница 18: ...h 18 Figure 4 on When water stops discharging from the nozzle turn the drain pump switch off c Some residual water will remain in the drain pump To remove this water lower the discharge nozzle 5 to the floor and clean with a towel or sponge d Any residual water in the tub may be removed by sponge drying e Place discharge nozzle 5 into socket 6 Note water will flow through hose if discharge nozzle ...

Страница 19: ... at least 10 2 cm 4 inches of water 2 Place the stem tip of a calibrated thermometer next to the tip of the Whirlpool thermometer 3 Turn on the turbine assembly 4 If the reading on the Whirlpool thermometer is not the same as that of the calibrated thermometer turn the external adjustment screw a so that the Whirlpool thermometer reading is identical to the calibrated thermometer 5 Re calibration ...

Страница 20: ...thermometer and turbine shall be disinfected and cleaned after each patient Disinfecting and Cleaning the Tub and Thermometer 1 Drain the tub following the draining instructions above 2 Verify that the turbine is off 3 Remove any loose objects or debris that may be present in the Whirlpool tub To disinfect use a stainless steel hard surface disinfectant per the manufacturer s instructions with one...

Страница 21: ...e all exposed surfaces with a mixture of suitable disinfectant solution per manufacturer s instructions Exposed surfaces shall remain wet for at least 10 minutes 8 Drain the turbine bucket into the tub and open drain 9 Rinse all exposed surfaces with warm or hot water 10 Fill the bucket with clean water and run turbine for five seconds to rinse impeller cavity ...

Страница 22: ...es not circulate No power to turbine Check the power source Reset the GFCI s if tripped Replace the fuses see instructions below Contact Whitehall Shaft has seized Contact Whitehall Turbine stops operation Motor is overloaded Check for blocked motor ventilation holes Check for excessive current load NOTE The motor is equipped with a thermal overload protector In an overheated condition the motor w...

Страница 23: ...c compatibility standard IEC 60601 1 2 as shown below Description Standard Specifications Radiated Emissions CISPR 11 30 MHz 1 GHz Class A Conducted Emissions AC Mains CISPR 11 150 kHz 30 MHz Class A Harmonic Emissions IEC 61000 3 2 10 min Class D no limits for 75W Flicker IEC 61000 3 3 120 min no limits for 75W Electro Static Discharge ESD IEC 61000 4 2 Contact 2kV 4kV 8kV Air 2kV 4kV 8kV 15kV Ra...

Страница 24: ...s such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this warranty Whitehall shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This wa...

Отзывы: