Aquatic Belmont II 4072620 Скачать руководство пользователя страница 1

OWNER’S MANUAL & 

INSTALLATION GUIDE

BUILDERS' 

CHOICE

   Note: 

 Read all instructions before proceeding with installation.  

 

 

 

All specifications are ± 1/4’’ and are subject to change without notice. Dimensions listed in inches (mm).

Installer: 

This booklet must be given to the product owner. Please add important information below.

 

Model # ___________________________________  Purchase Date ___________________________________

 

Serial #  ___________________________________      Distributor   ___________________________________

Содержание Belmont II 4072620

Страница 1: ...e subject to change without notice Dimensions listed in inches mm Installer This booklet must be given to the product owner Please add important information below Model _______________________________...

Страница 2: ...grams 8 Installation 9 Framing Installation Procedures 10 Electrical Connections 11 12 Final System Test Clean Up 13 OPERATION INSTRUCTIONS Your Whirlpool Bathtub What It Is And How It Works 14 Before...

Страница 3: ...he installation and service of your whirlpool should be performed ONLY by a quali ed electrician and plumber AQUATIC Product Warranty Registration Information 8101 E Kaiser Blvd Suite 200 Anaheim CA 9...

Страница 4: ...ler and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this ma...

Страница 5: ...te the whirlpool system if The bathtub isn t lled to required levels above jets You re pregnant until you ve consulted your doctor You re taking medications or drugs that may make you drowsy You re dr...

Страница 6: ...irlpool unit and circulation system carefully before installing WATER TEST the unit before installation If any damages or defects are observed DO NOT INSTALL Repack unit and notify distributor immedia...

Страница 7: ...ings spout handles valves etc are to be mounted on the unit be certain that the hot and cold water copper supply lines are located where there is ample room for mounting before setting the unit in pla...

Страница 8: ...and trace the ellipse Repeat this step three more times Once the tracing is complete cut out the ellipse The dimensions should be exactly 2 50 smaller than the unit A 6 x 12 150 x 305 Box outs B Leve...

Страница 9: ...ary shim feet until unit just rests on leveled ledges or framework Secure the unit by fastening the bottom feet to the sub oor with any construction adhesive The use of casting plaster or plaster of p...

Страница 10: ...ry loose at the top corners and pull outward away from frame To reinstall skirt panel Simply set panel in frame bottom side rst and push forward Lightly depress the tabs on the top of the panel while...

Страница 11: ...licensed electrician before using 4 Grounding Motors have a three prong electrical plug A ground should be run from J box receptacle to electrical house panel per code 5 Bonding A pressure wire conne...

Страница 12: ...Aquatic Builders Choice Owner s Manual Installation Guide ELECTRICAL CONNECTIONS Builders Choice Whirlpool Component Breakdown Electrical Requirements 120VAC 15 Amp GFCI outlet INSTALLATION INSTRUCTIO...

Страница 13: ...trician Malfunctions of the pump motor whirlpool controls or the circulating system should be reported to the distributor who supplied the whirlpool tub Clean up 1 Remove all construction residue and...

Страница 14: ...he bathtub until the water is at least 3 75 above the highest jet Never operate the whirlpool unless water is at least this high 3 Optional remote power switch A separate switch on your bathroom wall...

Страница 15: ...by rotating the face plate of individual jets counterclockwise for more pressure clockwise for less pressure OPERATION INSTRUCTIONS Figure 3 Figure 4 FCC CONSUMER INFORMATION Electrical Installation I...

Страница 16: ...Packaging Corporation to rectify this condition This may be obtained by contacting Aquatic at 800 945 2726 It is recommended that you follow the instructions provided by the manufacturer with the prod...

Страница 17: ...low all package instructions care fully Wear rubber gloves at all times and avoid contact with eyes skin clothing rugs and furnishings Make sure all residues are rinsed off thoroughly Rubber mats If y...

Страница 18: ...of bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia Marcescens These bacteria thrive on moisture dust...

Страница 19: ...ble form that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water supplier...

Страница 20: ...water at shaft 1 Shaft seal requires replacement 1 Contact Aquatic Leaking unions 1 O ring missing or damaged 2 Loose unions 1 Contact Aquatic 2 Tighten unions Vibration noise 1 Tub or tub plumbing is...

Страница 21: ...Aquatic 21 Builders Choice Owner s Manual Installation Guide BUILDERS CHOICE SERIES REPLACEMENT PARTS MAP...

Страница 22: ...IR 4a 8499FTG 5982MANIFOLD 1 AIR CHECK VALVE ASSEMBLY 5a 8078MOTOR PUMP MOTOR 0 75HP 5b 810250FTG TEE BULLHEAD 1 x 1 x 1 5 5c 8150UNION 1 5 PUMP UNION 5d 8409015FTG 1 5 90 DEG ELBOW ST 6a OPTION 8095H...

Страница 23: ...on TX 76011 3 The whirlpools and tubs must have been installed and maintained in accordance with good industry practice and the speci c Aquatic directions contained in the Owner s Manual and Installat...

Страница 24: ...AQUATIC Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Suite 200 Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANBLD F O D 9008 Rev 8 14...

Отзывы: