Page 18
FOLDING
The gap settings (Gap 1, Gap 2 & Gap 3) can then be adjusted by rotating the Roller
Gap Set Knobs (see FIG 10.1 on page 10).
When setting roller gaps, you
first adjust the gap to a value greater than that required
and then decrease the value to the required setting. (Do not set the gap, from a value lower
than that required).
(i) Measure the thickness of the sheet using a Digital Vernier Calliper.
(ii) Set roller GAP 1 to the vernier reading.
(iii) Set roller GAP 2 and roller GAP 3, (for the type of fold being produced), using the
GAP SET GUIDE table shown below.
Example 1:- When producing a
fold, if GAP 1 is 0.2 (X) then set GAP 2 to 0.4
(2 x X) and set GAP 3 to 0.4 (2 x X).
Example 2:- When producing a
fold, if GAP 1 is 0.3 (X) then set GAP 2 to 0.3 (X)
and set GAP 3 to 0.9 (3 x X).
IMPORTANT.
must
PROCEDURE.
Half K1
Gate
Half Fold on Knife 1
Half Fold on Knife 2
Half K1
Half K2
Letter
Concertina
Gate
Closed Gate
Engineering
FOLD TYPE
GAP 1
GAP 2
GAP 3
GAP SET GUIDE
X
X
X
X
X
X
X
2X
X
X
X
X
X
X
2X
2X
3X
3X
3X
3X
3X
Double
X
2X
4X
HALF
LETTER
DOUBLE
CLOSED GATE
ENGINEERING
GATE
CONCERTINA
FOLD TYPES
Operating the DigiFold Pro
Содержание DigiFold Pro
Страница 13: ...Page 13 SYSTEM BLANK PAGE Operating the DigiFold Pro DigiFold Pro ...
Страница 36: ...Page 36 FOLDING BLANK PAGE Operating the DigiFold Pro ...
Страница 46: ...BLANK PAGE FOLDING Page 46 ...
Страница 55: ...Page 55 SYSTEM BLANK PAGE DigiFold Pro ...
Страница 63: ...Page 61 SYSTEM DigiFold Pro ...