Maintenance
B : Seed Distribution
f)
f)
Metering devices
-
Never leave seed for any length of time in the hopper
-
Open shutters (1) and flaps (2) during the storage period
-
Never lubricate or grease metering devices and seed pips
-
Checks – Incorrect setting of flaps (2) may induce oversowing in the course of work.
It is recommended to check and adjust if necessary after each sowing period-
-Set the flap lever to index 1
-Begin with visually assessing the distance between the flap and the peg
wheel
-If necessary, insert a 6mm spacer (3) between the flap and large space peg
wheel.
Adjust the distance with screw (4).
34
Содержание Tandem Uni-Drill DP400A
Страница 9: ...Safety Regulations Safety Stickers 9 ...
Страница 17: ...Start Up G TURBINE 17 ...
Страница 23: ...Settings A Distribution Settings 23 ...
Страница 32: ...Settings H Tramline Track Width 32 ...
Страница 41: ...Flow Rate Tables Calibration Procedure 41 ...
Страница 42: ...Flow Rate Tables Calibration Procedure 42 ...
Страница 43: ...Flow Rate Tables Calibration Procedure 43 ...
Страница 44: ...Flow Rate Tables Calibration Procedure 44 ...
Страница 45: ...Flow Rate Tables Calibration Procedure 45 ...
Страница 48: ...DP400A and DP600A Parts booklet 2002 seeding line ...
Страница 52: ...2002 DP600A markers ...
Страница 54: ...Marker Circuit Diagram ...
Страница 55: ...W Seed box hopper extension ...
Страница 56: ...W Seed box Peg Wheels ...
Страница 57: ...W Seed box Distributor Assembly ...
Страница 58: ...W Seed box Distributor Assembly ...
Страница 59: ...W Seed box Variator Assembly W Seed box Variator Assembly ...
Страница 60: ...W Seed box half width shut off ...
Страница 61: ...W Seed box Venturi System ...
Страница 62: ...W Seed box Drive Wheel Assy ...
Страница 63: ...W Seed box Wind turbine Assy ...
Страница 64: ...W Seed box Air Intake ...
Страница 65: ...W Seed box RDS system ...
Страница 66: ...W Seed box MS Variable seeding ...