ID
Index Name / Setting
Unit Description
REFV (-2)
Analog reference
(-1)
Not defined
Off (0)
No function
START (1)
Start motor control
INV (2)
Inverse reference value
STOP (3)
Execute quickstop
HALT (4)
Disable feed
LCW (5)
Inching in positive direction
LCCW (6)
Limit switch negative direction
INCH_P (7)
Jog Positive
INCH_N (8)
Jog Negative
HOMST (9)
Start homing
HOMSW (10)
Reference switch
E_EXT (11)
External error
WARN (12)
External warning
RSERR (13)
Reset alarm
MAN (14)
Switch control location selector
(15)
Not defined
PLC (16)
Used in PLC
PLC_IR (17)
PLC interrupt
MP_UP (18)
Motor potentiometer Negative
MP_DOWN (19)
Motor potentiometer Positive
(20) - (20)
Not defined
TBEN (21)
Enable selected table index
TBTEA (22)
Write actual position into selected table index
TAB0 (23)
Binary table index 2^0
TAB1 (24)
Binary table index 2^1
TAB2 (25)
Binary table index 2^2
TAB3 (26)
Binary table index 2^3
EGEAR (27)
Start / stop Egear
REFANAEN (28)
Enable analog reference
(29)
Not defined
(30)
Not defined
Table 9.12: “Analog inputs” function selectors (continue)
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD
Servo
Drive -
Device
Help
2
4
5
9 Input/Output settings
ID
Index Name / Setting
Unit Description
(31)
Not defined
(32)
Not defined
(33)
Not defined
JOG_EXT_POS (34)
Jog Positive (extended mode)
JOG_EXT_NEG (35)
Jog Negative (extended mode)
FAST_DISC (36)
Fast discharge
LIM_OFF (37)
Limits (torque and velocity) off
LOCK_POS (38)
Lock positive direction
LOCK_NEG (39)
Lock negative direction
BRAKE_ON (40)
Switch off motor break at once
PWR_REL_DIRECT (41)
Direct activation of power relay (with 1000ms
delay)
(42)
Undocumented value
(43)
Undocumented value
(44)
Undocumented value
(45)
Undocumented value
(46)
Undocumented value
(47)
Undocumented value
(48)
Undocumented value
Table 9.12: “Analog inputs” function selectors (continue)
9.4.3 Analog input scaling
Analog input scaling makes it possible to convert the analog input value to the
process variable by using a gain factor, offset, and backlash. The figure shows how
this scaling function works. Entering the desired voltage ranges will yield the values
for the offset (P 428 - CON_ANA_Offset) and gain (P 429 - CON_ANA_Gain).
Depending on the function selected for the ISAxx analog input with the function
selector, it will be possible to use the “Options...” button to configure additional
process variables such as “the backlash in rev/min” (when using an analog setpoint,
REFV).