8.1 Settings
When it comes to the drive settings for motion profiles, the settings that need to be
configured relate to the following: control, units, and commands.
Fig. 8.1: Motion profile dialog box
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD Servo Drive - Device Help
161
8 Motion profile
①
Standardization profile
Standard/CiA 402
SERCOS
User-defined
②
Settings used to configure the control and setpoint channels
Control/Reference
Profile
Interpolation
Limitation
Reference filter
Smoothing
③
Stop ramps / behaviour
to Shutdown
to Disable
to Halt
to Quickstop
to error
Setting of quick-stop ramp
④
Used to select a homing mode
Homing method
Speeds (cam/zero point search)
Acceleration
Offset
Homing maximum distance
Legend to “Motion profile” dialog box