PARISON CONTROLLER
moog
82
MAN145-UM-D01A-EN
Moog Italiana srl - Bergamo
Open loop:
in open loop mode is possible to
move the accumulator down pushing
DOWN
key. Pushing
UP
key it is possible to move the
accumulator Up because the output becomes
negative and the material moves up the
accumulator. When the accumulator is in
mechanical stroke you have to confirm the Full.
or Empty. values for the calibration.
Figure 80
Calibration:
in calibration mode set
Start
to
YES and the accumulator automatically
searches for the empty position. Pushing
UP
key it is possible to move the accumulator Up
because the output is negative and the material
moves up the accumulator. When the
accumulator is in position you have confirm the
values for the calibration.
Inv. Output:
Select YES to reverse the analog Output polarity.
Inc. Up / Inc. Down:
these variables correspond to the acceleration value of the output command (expressed in
mV/s or mA/s). It is the ramp increment or decrement value on the analog Output.
Inc. Up
determines the slope
ramp tMax value.
Inc. Down
determines the slope ramp towards Min value.
The accumulator uses analog Input 4 to read the position and analog Output 4 to drive the extrusion (if the digital
accumulator is not enabled).
Figure 81
V. Full
and
V. Empty:
In these fields the full and the empty values are
visualized in mV.
4.9.2
Run parameters.
Figure 82
Time control extrusion:
Enable the control time during the
extrusion. If the control is set to NO the accumulator extrusion
speed is managed in open loop. In this case output voltage
depends on the profile assigned by accumulation. The profile
point to be output depends on the same accumulator position.
If the control is set to YES the accumulator extrusion speed is
managed in closed loop. In this case the profile is output in a
preset total time with a speed setpoint reflecting the profile.
The position closed loop performs the extrusion in order to follow the velocity profile.
Enable start correction:
Enable the correction on the injection start position.
If this correction is
NO
, the filling quota passed to the head is calculated always from “end of filling” point to “end of
extrusion” point.
Содержание IMI220-145D001
Страница 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Страница 24: ...PARISON CONTROLLER moog 24 MAN145 UM D01A EN Moog Italiana srl Bergamo 2 5 8 Position Accumulator Figure 25...
Страница 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Страница 44: ...PARISON CONTROLLER moog 44 MAN145 UM D01A EN Moog Italiana srl Bergamo 3 7 Terminal measures Figure 36 UNIT mm...
Страница 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Страница 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Страница 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...