PARISON CONTROLLER
moog
Moog Italiana srl - Bergamo
MAN145-UM-D01A-EN
73
4.7
Head Setup 2.
Figure 67
Setup 2 Head 1:
Setup 2 Head 1 page.
Access:
From Setup1 Head1 Page with key
F7
. (only with acc. position)
Use:
With accumulator position it is possible to activate the parison length control. Comparison
between photocell signal and programmed point.
At photocell signal, the currently issued point is detected and compared with a reference value. The difference
between the two values (in points) is the error. If the error is lower than Minimum error, no correction is made. If
the error is greater than Maximum error it is possible to decide whether making the maximum correction or making
no correction at all. If the error is between minimum and maximum a proportional correction is calculated. The
correction is made by changing the additional weight value on the regulator (Trim). A single photocell drives all the
regulators.
4.7.1
Control length parameters.
Figure 68
Control
length
profile
(Only with accumulator position)
:
Enable
the length control on the profile.
Point
for
control:
Set the reference point for the control.
Maximum
error:
Maximum allowed error calculated between the
programmed point and the point triggered by the photocell signal.
Minimum
error:
Minimum allowed error.
Maximum
correction:
correction to be applied if the calculated error is greater of the maximum allowed error.
Correction
type:
no correction or maximum correction if the error is greater of the maximum allowed error.
When the error is smaller than the
Minimum error
no correction is made. When the error is included between the
Minimum error
and the
Maximum error
the correction is proportioned to the
Maximum correction
.
Содержание IMI220-145D001
Страница 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Страница 24: ...PARISON CONTROLLER moog 24 MAN145 UM D01A EN Moog Italiana srl Bergamo 2 5 8 Position Accumulator Figure 25...
Страница 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Страница 44: ...PARISON CONTROLLER moog 44 MAN145 UM D01A EN Moog Italiana srl Bergamo 3 7 Terminal measures Figure 36 UNIT mm...
Страница 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Страница 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...