PARISON CONTROLLER
moog
66
MAN145-UM-D01A-EN
Moog Italiana srl - Bergamo
4.6.1
Check wirings.
To check the correct wiring:
Choose
open loop
calibration.
With the UP/DOWN keys
verify the correct movement
: if the UP key is pressed, the moving part has to
move up, if the DOWN key is pressed the moving part has to move down.
o
If the movement is OK :
Check the bar graphs movement (yellow and blue). If bar graphs are moving in the same
direction, also the input is OK and it is possible to perform the calibration in close loop.
If the bar graphs are moving in opposite directions, reverse the input polarity by inverting
the parameter Inv. input in the head setup page
o
If the movement is not OK :
Reverse the input polarity by inverting the parameter
Inv. output
in the head setup page
After this, the movement should be correct. If bar graphs are moving in the
same
direction
, also the input is OK and it is possible to perform the calibration in close loop.
If the bar graphs are moving in
opposite directions
, reverse the input polarity by inverting
the parameter
Inv. input
in the head setup page
Содержание IMI220-145D001
Страница 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Страница 24: ...PARISON CONTROLLER moog 24 MAN145 UM D01A EN Moog Italiana srl Bergamo 2 5 8 Position Accumulator Figure 25...
Страница 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Страница 44: ...PARISON CONTROLLER moog 44 MAN145 UM D01A EN Moog Italiana srl Bergamo 3 7 Terminal measures Figure 36 UNIT mm...
Страница 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Страница 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Страница 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...