Moog ACV with CANopen bus interface
8 Diagnostics
Fault reaction
B99224-DV018-D-211, Rev. A, October 2018
273
41, 42, 43, 44
5232
Encoder cable break / SSI error
26, 31
5233
Analog input 0: supply cable error / signal out of range
27, 32
5234
Analog input 1: supply cable error / signal out of range
28, 33
5235
Analog input 2: supply cable error / signal out of range
29, 34
5236
Analog input 3: supply cable error / signal out of range
30, 35
5237
Analog input 4: supply cable error / signal out of range
20, 21
5238
Main stage actual spool position out of range / cable break
45
5410
Power driver
46
5510
RAM
47
5520
EPROM
48
5530
EEPROM
51
6010
Software reset (watchdog)
50
6101
Software coding
52
6102
Interrupt time exceeded
53
6103
Task time exceeded
49
6104
Out of memory
69
6201
Event handler
55
6311
Node identifier data
56
6312
User data
57
6313
Restore data
58
6314
Factory data
59
6315
Calibration data
60
6316
Diagnosis data
54
6320
Parameter error
119
7002
I2C_general_fault
90, 113, 118
8100
Fieldbus communication
70
8101
Local CAN communication
91
8110
CAN overrun
71
8111
Local CAN overrun (objects lost)
92
8120
CAN in error passive mode
72
8121
Local CAN in error passive mode
110
8130
Life guard error or heartbeat error
93
8140
CAN recovered from bus off
73
8141
Local CAN recovered from bus off
94, 114
8231
RPD01 time out
95
8232
RPD02 time out
96
8233
RPD03 time out
97
8234
RPD04 time out
102, 116
8235
TPD01 time out
103
8236
TPD02 time out
104
8237
TPD03 time out
105
8238
TPD04 time out
111
8239
SYNC producer time out
112
823A
SYNC consumer time out
98, 115
8241
RPD01 data
99
8242
RPD02 data
100
8243
RPD03 data
Fault code
Error code
defined in Device Profile Fluid Power
Error description
Table 114: Possible error codes depending on fault codes (part 2 of 3)