Moog ACV with CANopen bus interface
6 Signal routing and scaling
Drive transducer interface
B99224-DV018-D-211, Rev. A, October 2018
79
6.3.10.2 Object 0x6221: Maximum pressure
This parameter defines the maximum transducer signal (when pressure offset equals 0).
6.3.10.3 Object 0x6224: Minimum transducer signal
This parameter defines the transducer signal when the pressure is minimal (when pressure offset equals 0).
6.3.10.4 Object 0x6225: Maximum transducer signal
This parameter defines the transducer signal when the pressure is maximal (when pressure offset equals 0).
6.3.10.5 Object 0x6222: Pressure area
This object shall provide the cylinder area corresponding to a pressure transducer. In Moog firmware this pa-
rameter consists, but is not used for any calculation.
6.3.10.6 Object 0x6223: Pressure offset
This parameter defines a pressure offset which is added to the two point scaling function defined by the four
parameters before.
Drive_ActualValueConditioning
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6221
1
MaximumPressure
INT32
rw
N
INT16
16384
Drive_ActualValueConditioning
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6224
1
MinimumTransducerSignal
INT32
rw
N
INT16
16384
Drive_ActualValueConditioning
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6225
1
MaximumTransducerSignal INT32
rw
N
INT16
16384
Drive_ActualValueConditioning
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6222
1
PressureArea
INT32
rw
N
INT16
0
Drive_ActualValueConditioning
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6223
1
PressureOffset
INT32
rw
N
INT16
0