RP424PFC Indoor Gas Fireplace
Page 57
XG0781 - 151104
Maintenance
Step 5:
Disconnect the wires connected to the switch. The blue wire
connects to the closest terminal and the grey wire connects to the
farthest terminal when viewed from the front of the fireplace. Do not
connect a wire do the center terminal.
Replace the .70 switch:
Step 1:
Disconnect power and gas supply to the fireplace.
Step 2:
Remove glass barriers. See
Section 10
for installation and
removal of glass. Note: if removing glass from one side only, take
precautions against dirt and damage to the remaining sides.
Step 3:
Remove the access panel and inner valve cover. See
Accessing the Valve
.
Step 4:
The vacuum switches are mounted above the valve. Begin
by removing the silicone tubes connected to the bottom of the switch.
The clear tube connects to the black nipple and the red tube connects
to the grey nipple.
Figure 115.
Figure 116.
Disconnect blue wire.
Figure 117.
Disconnect grey wire.
Step 6:
Remove the screws securing the switch to the mounting
bracket.
Figure 118.