RP424PFC Indoor Gas Fireplace
Page 21
XG0781 - 151104
Installation
Installation of Electrical Supply
The
RP424PFC
is supplied with an external electrical control
box pre-wired by the factory. The control box is connected to the
fireplace with a 30 foot long 9-conductor cable that will communicate
with the fireplace. Extension cables are available through your
Montigo dealer only.
A 20ft low voltage black / white cable is provided for connection
to a single pole on/off switch. The length of this cable can be
extended up to a length of 100ft using a cable of equal or greater
capacity. This system operates on 24VAC. Do not connect this
switch circuit to an external power source.
Install the single pole accent lighting ON/OFF switch (not supplied)
and/or the optional remote control. Do not use a dimmer switch for
accent lighting.
Optional remote control available through your Montigo Dealer.
Do not use third party remote controls without the approval from
Montigo.
Section 4: Wiring
Installing the Fireplace Control Box
Install the Fireplace Control Box in an accessible location maintaining
a minimum of 1" clearance on all sides. The location should be where
maintenance, adjustments and service may be easily made.
Conduit & Wiring clearances
Connect the power vent harness as outlined in the previous section.
Ensure that the proper clearances are maintained for the wiring
and conduit. When installing the wiring it must never run above
the vent run and it must be at least 1" clear of all venting.
Wire
Note:
If any of the original wire supplied with the appliance
is replaced, it must be with the same or it's equivalent.
1" Clearance
Installations in Canada
must be electrically grounded in
accordance with
CSA C22.1
Canadian Electrical Code Part 1
and/or Local Codes.
Installations in the USA
must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code,
ANSI/NFPA 70.
Figure 34.
Control Box
Left-side View
Right-side View
Power Vent
Harness
Power Ven
t
Speed Control
Post Purge
Timer (3 min.)
Prepurge
Timer (1 min.)
Power
Vent Fus
e
(5A)
Power Vent
Connector
Control
Panel Fus
e
(
5A
)
LED
Power
Indicator
Heat Sensor /
Conmustion Switch
Figure 35.
Conduit and Wiring
LED Indicator
Fuse
115V
Power Supply
Wall Switch Control
cabl
e
115V
Outlet
Figure 33. Control box Diagram