CLEANING STORAGE CABINET
WARNING: DISCONNECT ELECTRICAL
POWER SUPPLY BEFORE CLEANING ANY
PARTS OF THE UNIT.
STORAGE CABINET: Remove the drawer from
the drawer frame modules, use warm soapy
water to clean storage cabinet doors.
NEVER
use cleaners containing gritty, abrasive
materials, bleach or harsh chemicals. Rinse
thoroughly and dry with a clean soft cloth.
Always rub in the same direction as the grain
patter of the stainless steel
WARNING: DISCONNECT ELECTRICAL
POWER SUPPLY BEFORE CLEANING ANY
PART OF THE UNIT
The condensing unit coil must be cleaned
regularly on self-contained models for optimal
performance. The operating environment will
affect the required frequency of cleaning.
However, the condenser should be cleaned at
minimum of once every month. Air must be able
to freely circulate through the condenser. Unit
performance and operating efficiency are
significantly affected by the amount of the air
passing through the condenser. Condenser fins
that are clogged with dirt and grease greatly
reduce required heat transfer to air flow. Failure
to keep the condenser clean may cause
premature compressor failure, which will not be
covered by the warranty. The condensing unit is
located behind the louvered panel in the
compressor compartment. Remove panel by
lifting it up and pulling the bottom out. Carefully
clean dirt and lint from the condenser coil using
a vacuum cleaner or soft brush.
Do not use a
wire brush.
An approved condenser
degreaser must be used to remove grease.
Replace louvered panel by installing top of the
panel into
track and pushing in the bottom so it fits inside
the opening, reconnect electrical supply.
CONDENSER COILS
WARNING: DISCONNECT ELECTRICAL
POWER SUPPLY BEFORE CLEANING ANY
PARTS OF THE UNIT.
Condenser Coil should be cleaned regularly to
allow air circulation that will ensure proper
operation and efficiency. Failure to clean the coil
at regular intervals can cause compressor
failure and/or malfunction and will void the
warranty. A minimum of a monthly cleaning is
required.
(See operating instructions to prevent premature
failure of components.)
CONDENSING COIL PREVENTATIVE
MAINTENANCE (MONTHLY)
NOTE: THE VACUUM “BLOW MODE” IS TO
BE
USED
WHEN
CLEANING
THE
CONDENSER COIL.
Follow these steps:
A. Remove grille; use vacuum and soft brush to
dislodge and remove dust on and in the coil.
B. Place damp rags around condensing fan
motor bracket to collect airborne dust.
C. Using vacuum (in blowing mode), blow air
through condenser coil and into the fan.
Make certain to blow entire surface of
condensing coil to assure that all entrenched
dust is removed.
MAINTENANCE PROCEDURES
14
Содержание FB-108-R
Страница 26: ...BLACK WIRING DIAGRAM RB SC R REFRIGERATED BASE SELF CONTAINED REMOTE 21...
Страница 27: ...WIRING DIAGRAM FB SC R FREEZER BASE SELF CONTAINED REMOTE 22...
Страница 28: ...COMPRESSOR COMPARTMENT EXPLODED VIEW 23...
Страница 29: ...EVAPORATOR COIL 24...
Страница 30: ...TOP DRAWER ASSEMBLY EXPLODED VIEW 25...
Страница 31: ...BOTTOM DRAWER ASSEMBLY EXPLODED VIEW 26...