7
ASSOCIATION
•
The sensor supports two groups with 5 nodes/group.
•
Group 1 = Lifeline
•
Group 2 = On/Off Control
•
All triggering reports and low voltage reports will be sent to the
associated nodes.
•
Association is used for other grouping devices chain reaction.
WAKE UP NOTIFICATION
Remove the rear cover to put the sensor in "Wake Up Mode" for
receiving all command classes from the controller and sending a "Wake
Up Notification" message after 10 seconds. If the sensor receives a
"Wake Up No More Information" command, it will go into sleep mode
after 10 seconds. It will process all the commands after sending the
"Wake Up Notification".
AUTO WAKE UP
Use the "Wake Up" command to setup the waking time and send the
"Wake Up Notification" to the controller. You can then use commands to
change the Auto Wake Up interval from 10 minutes to 194 days, in 200
second increments. The default Auto Wake Up interval is 24 hours.