10
49-80152 Rev. 8
Installation Instructions
1
DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
■ Use a level to draw the cooktop centerline location.
Draw the line to ceiling height.
■ Measure desired distance from the bottom of the hood
to the cooking surface, 30” min. to 36” max.
NOTE:
If you are installing the hood with duct covers, be
sure to read “Optional duct cover accessories” section
found on page 4. Exact installation height may be
determined by use of one or more duct covers.
■ Use a level to draw a straight horizontal pencil line
indicating the bottom of the hood.
■ From the line indicating the bottom of the hood,
measure 15-3/8” up and draw another line for the
location of the wood support. See illustration.
FOR VERTICAL (Straight Up) DUCTING
■ Use a level to draw a centerline from the bottom of the
hood to ceiling or soffit.
■ If venting out the ceiling, extend the centerline forward
on the ceiling or soffit.
■ Locate the centerline of a 10-1/2” hole on the ceiling
or soffit by measuring 6” from the wall.
FOR DUCTING THROUGH REAR WALL
■ Measure 9-7/8" above the marked line for the top of
the hood. At the centerline, mark location for a 10-1/2"
diameter hole.
NOTE:
Minimum ceiling height for REAR WALL
EXHAUST with duct covers is 8'4" when installing at 30"
above countertop using 10" elbow.
House Wiring Location
■ The junction box is fastened to the back of the hood
on the right side.
■ The recessed back side of the hood provides a large
area for the house wiring to exit the wall and be routed
to the rear knockout and junction box.
■ The location for the house wiring depends on the
installation height of the hood and the width of the hood.
■ Remove junction box cover and knockout. Install
strain relief.
Alternate Knockout Locations
If the installation requires, the junction box can be
relocated from the back to the top of the hood. Remove
3 screws, align box to top knockout and secure with
original screws.
■ Remove junction box cover and knockout. Install strain
relief.
*Depending on Hood width
and Installation Height.
18-13/16" for 48" Models
12-13/16" for 36" Models
9-13/16" for 30" Models
Electrical
Area
8-3/8"
6-1/2"
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
1” = 2.5 cm; 1’ = 0.3 m