ARDAC WACS-2 Specification and Adjustment Manual
44X477 Rev. 8
05/ 16/ 03 4-15
4. Using only a Money Controls 49x307 Calibration Card, insert the card into the acceptor. As
shown below:
5. The card is drawn into the acceptor and returned after a second.
6. The message “Calibration Passed” and the new calibration values display on the monitor. The unit
is calibrated.
7. At the end of its calibration sequence, the acceptor automatically leaves Auto Calibrate Mode.
When the Message Screen displays again, the Auto Calibration status line will read:
Autocalibrate: DISABLED