VFI33 Vent Free Gas Fireplace System
20307670
23
ELECTRICAL WIRING
–
FAN
IMPORTANT:
Always check local building codes. The
installation must comply with local regulations as well as
the national electric codes.
If any of the original wire as supplied with the fireplace must
be replaced, contact dealer for proper replacement wiring
harness. (Refer to parts list for correct part number). 120
volts, 60Hz, 1 amp.
110/115
V.A.C.
Fan Switch
OFF
Black
White
Green
ON
Thermostat
Control
Blower
Motor
Black
FP2783
DIS wiring
Figure 23 -
VFI Wiring Diagram
Electrical power cord (plug) can be routed to exit the
VFI33 on either the left side or the right side. Remove cord
protector from side of unit, route power cord through hole
opposite side. Reinstall cord protector.
WARNING: Never attempt to service
heater while it is plugged in, operating,
or hot. Burns and/or electrical shock could
result.
WARNING:
This fireplace has a three-
prong, grounded electrical plug. This
plug helps protect you against electrical
shock. Only connect plug to a properly
grounded, three-prong receptacle. Do not cut
or remove the grounded prong from this plug.