VFI33 Vent Free Gas Fireplace System
34
20307670
ANNUAL CLEANING/INSPECTION—
Refer to parts diagram for location of items discussed
below.
Annual inspection and cleaning by your dealer or qualified
service technician is recommended to prevent malfunction
and/or sooting.
Remove logs, handling carefully by holding gently at each
end. Gloves are recommended to prevent skin irritation
from ceramic fibers. If skin becomes irritated, wash gently
with soap and water. Refer to manual for correct log
placement.
•
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush or pipe cleaners.
Failure to keep air intake holes clean will result in
sooting and poor combustion.
•
Inspect and clean all burner ports.
•
Inspect ODS pilot for operation and accumulation of
lint at air intake holes.
•
Verify flame pattern and log placement for proper
operation.
•
Verify smooth and responsive ignition of main burner
and rear burner.
CLEANING AND SERVICING
PERIODIC CLEANING—
Refer to parts diagram for location of items discussed
below.
•
Do not use cleaning fluid to clean logs or any part of
heater.
•
Brush logs with soft bristle brush or vacuum with
brush attachment.
•
Vacuum loose particles and dust from the front and
rear burner, control and piezo covers and grate weld-
ment.
•
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush, or pipe cleaners.
Failure to keep air intake holes clean will result in
sooting and poor combustion.
•
External case should be dusted and wiped with a
wet soapy cloth.
WARNING:
Turn off heater and allow to cool before cleaning. Disconnect electrical
power before cleaning or servicing.