HDV Series Direct Vent Gas Fireplace
CleARANCeS
12"
Maximum
Depth
12"
Minimum
72"
Minimum
Minimum 6"
From Both
Side Walls
FP2281
wall clg clear
Ceiling
Combustible Mantel
FP8
CleARANCeS to CoMBuStIBleS
MANtel CleARANCeS
Note:
The combustible area around the fireplace must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
Figure 4 -
Clearances from the Mantel, Ceiling, and Side Wall
Figure 5 -
Mantel Clearances
6”
7”
8
56M
”
9
56O
”
10
6M
”
12”
2
56O
”
4”
6”
8”
10”
12”
FP2282
mantel clearance
Wall
Insulation Board
Header
Side View
Standoffs
Top of
Fireplace
Opening
FP8
45°
1” 1
56O
”
3
56O
”
4
56O
”
2
56O
”
3”
5”
6”
FP2283
mantel leg clearance
top View
Stud
Wall
Combustible
Area
Hood
Side of Fireplace
Opening
FP83
Follow these instructions carefully to ensure safe installation. Failure
to follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring,
the appliance shall be installed on a metal, wood or noncombustible
material panel extending full width and depth of the appliance.
W
ARNING
W
ARNING
Never obstruct or modify the air inlet or
outlet grilles (louvers). this may create a
fire hazard.