HDV Series Direct Vent Gas Fireplace
8
56D3048
PRe-INStAllAtIoN INFoRMAtIoN
FIRePlACe loCAtIoN
Plan for the installation of your appliance. This includes determining where the unit is to
be installed, the vent configuration to be used, framing and finishing details, and whether
any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult
your local building code agency to ensure compliance with local codes, including permits
and inspections.
The following factors should be taken into consideration:
•
Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to com-
bustibles
must be maintained.
•
This fireplace may be installed along a wall, across a corner, or use an exterior chase.
Refer to
Figure 3
for suggested locations.
•
Location should be out of high traffic areas and away from furniture and draperies due
to heat from appliance.
•
Never obstruct the front opening of the fireplace.
•
Do
not
install in the vicinity where gasoline or other flammable liquids may be stored.
•
Vent pipe routing. Refer to the
Venting
section found in this manual for allowable venting
configurations.
•
These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z33.1/
NFPA 54 — (current edition), the Uniform Mechanical Code — (current edition), and
Local Building Codes for specific installation requirements.
Y
E
A
B
C
D
F
Y
B
X
LU584-1
Locating unit
2/4/99 djt
Figure 3 -
Locating Gas Fireplace
** Island (C) and room divider (D) installation is
possible as long as the horizontal portion of vent
system (X) does not exceed 0'. Refer to
Installing
Horizontal Termination Configuration
on
Page 13
.
* When you install your fireplace in (D) room
divider or (E) flat on wall corner positions (Y), a
minimum of 6" clearance must be maintained from
perpendicular wall and front of fireplace.
A Flat on Wall
B Cross Corner
C Island**
D Room Divider*
E Flat on Wall Corner*
F Chase Installation
Y 4" Minimum