XL-2 Manual
Customizing your controller
Revision 1.1
Mold-Masters
®
Page 25
Functions of Menu Items
External Alarm Output Activation Items
There is a remote alarm connector located on the side of the
cabinet, which has a relay to turn on audible alarms, or lights, or to
turn off other machinery. Parameters in “External Alarm Output
Activation” are provided for the user to choose under what
circumstance to trigger the alarm relay. External alarm will be
switched on if the specific instance happens and its menu item is
set to 1. For instance, if thermocouple break happens and the
value in “Abr” is set 1, external alarm will then be triggered. To
disable the alarm triggering in any specific condition, set its value
to “0”.
Alarm Items
In “Alarm” parameters, you may adjust either over or under
temperature alarm limits. If these temperatures are exceeded, the
alarm relay on the card changes state, and
Led will be lit up.
There is a remote standby connector is available on the side of
the cabinet. The user can use this input point to switch the XL-2
into Standby Mode remotely as long as Menu Item “El” is set to 1.
To disable this feature, simply set its value to “0”.
Soft Start Items
Parameters in “Soft Start” will define the heating profile. Controller
will have a virtual model built to map the tool and heater
characteristics, these parameters do not need to be adjusted
unless there is an unusual large heating plate.
Special Operating Mode Items
Control mode is used when a thermocouple fails, the operation
can still carry on. The controller card holds historical power level
for that specific zone after reaching set temperature and
maintaining for at least 5 minutes. This mode will be kicked in if
“not” is set to 1 and thermocouple break happens.
The user can enable special operating mode in the Function
Menu; however, the mode cannot be turned on if its corresponding
enable setting is set as “0” in the program menu. For example, if
“EHd” item is set to “0”, manual mode cannot be activated
completely, which is for preventing accidental change of mode.
Others Items
These parameters are to set over current limit, standby level,
boost level, and temperature scale. Max. temperature limit item is
to set maximum temperature permitted fro this specific zone. Item