![Mold-Masters TempMaster XL-2 Series Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/mold-masters/tempmaster-xl-2-series/tempmaster-xl-2-series_user-manual_1823674017.webp)
XL-2 Manual
Setting up your controller
Revision 1.1
Mold-Masters
®
Page 17
Setting Boost up level
Before you activate Boost function, you must first configure the
amount. When boost is activated, the controller will raise up to
boost temperature. Boost up level is to determine the increment
for the zone during boost function activated. Please note that, on
a slow responding manifold, if you set a high boost temperature,
the zone is unlikely to reach your set boost temperature before the
boost time limit expires.
Boost up level from factory setting is 75°C or 135°F, which means
if your controller is set at 200ºC, temperature will raise to 275ºC.
On the other hand, if controller is set in Fahrenheit, set-
temperature is at 400ºF; temperature will boost up to 535ºF.
1. From the Temperature Display Screen, press and hold
button for at least 2 seconds until you get into Function Menu.
2. Use to scroll to “Prog” then press button to enter.
3. Use to scroll to parameter ”tUP”. You will see the bottom
display flashing.
4. Press to get access to change parameter setting. The
bottom display should stay.
5. Use
or change to your desire setting.
6. Press to store the change. The bottom display should be
flashing again.
7. To return to Temperature Display Screen by pressing .
Setting Standby Level
Before you activate Standby function, you must first configure the
amount. When standby is activated, the controller will reduce to
standby temperature. Standby level is to determine the
decrement for the zone during standby function activated.
Standby level from factory setting is 100°C or 180°F, which means
if your controller is set at 260ºC, temperature will reduce to 160ºC.
On the other hand, if controller is set in Fahrenheit, set-
temperature is at 400ºF; temperature will drop to 220ºF.
1. From the Temperature Display Screen, press and hold
button for at least 2 seconds until you get into Function Menu.
2. Use to scroll to “Prog”. Press to enter Program Menu.
3. Use to scroll to parameter “tdn”. You will see the bottom
display flashing.
4. Press to get access to change parameter setting. The bottom
display should stay.
5. Use or