Table 5-5 Utilities Parameters
Function
Description
Notes
Software Version
Shows which version of the software
is installed.
Not user-configurable.
Supply Voltage
Sets the system supply voltage, which
is used to calculate the watts display.
• This is normally the phase-neutral
voltage on a Star supply and the
phase-phase voltage on a Delta
supply.
Maximum supplied voltage is 600V.
Temperature
Precision
Sets the resolution for the Actual
temperature seen on the Display
page.
Floating point scale
: displays
temperature to within one tenth of a
degree.
Integer scale
: rounds the displayed
temperature to the nearest whole
degree.
User Password
If set to [
Enabled
] then all password-
protected functions need either a
User (Level 1) or System (Level 2)
authorization as shown in Table 5-6.
If set to [
Disabled
] then all the lower
functions become available without the
need for any password.
Note:
Only those higher functions that
require a System (Level 2) password
retain their password protection.
Utilities Parameters - continued
5-19
SETUP
© 2021 Mold-Masters (2007) Limited. All Rights Reserved.
M1 Plus Controller User Manual