Section 4 - Overview
WARNING
Ensure that you have fully read “Section 3 - Safety” before connecting or
operating the controller.
4.1
Specification
The following are general specifications. The actual controller / console
supplied may have contractual variations and differ in some specified options.
Table 4-1
General Specifications
Alarm Output
Closing Contact Relay 5 Amp max
Control Range
0 - 450 Celsius (Centigrade), 32-842 Fahrenheit
Data Communications
RS-232 serial, DB9 male connector
Heater Tool Connector
Harting type Han E or equivalent
Mains Voltage Output
Pattern
Burst-fired or zero voltage crossover
Output Overload
Protection
High-speed semiconductor fuse links
Overload Protection
Miniature Circuit Breaker
Printer Output
Connector
USB port
Relative Humidity Limit
90% [non-condensing]
Supply Earth-Leakage
Trip
300mA
Note
: this is for tool protection
Supply Voltage
415 Volts 3-phase 50/60 Hz with neutral. Other
available include 240/380/400 and 600 volts in Star
or Delta configuration
T/C Tool Connector
Harting type Han A or equivalent
Temperature Control
Method
Closed loop (Auto) or open loop (Manual) with HR
software
Temperature Scale
Celsius (Centigrade) or Fahrenheit
Voltage Bandwidth
Stable within (20% supply voltage swing)
4-1
OVERVIEW
© 2021 Mold-Masters (2007) Limited. All Rights Reserved.
M1 Plus Controller User Manual