7.14.3 Event-Trigger
In the case where a system event is used as a trigger event, the user has
to enter the full qualified name of the event or select it from a list of defined
system events.
7.14.4 Alarm-Trigger
System alarm triggers can be selected from a list of all defined alarms. An
alarm is only fully identified through the additional specification of four values
for the Alarm-Sub-Ids. If the value -1 is specified for a Sub-Id every occurring
alarm, irrespective of its Sub-Id, will act as a trigger at this point (Sub-Id-
"Wildcard").
7.14.5 Settings - Parameter
The parameter selection enables selection of system variables to be
recorded. A maximum of 12 variables can be selected. The following types of
system variables can be logged:
•
all INT-types (SINT, INT, DINT, LINT, USINT, UINT, UDINT, ULINT)
•
all REAL-types (REAL, LREAL)
•
all Bit-types (BOOL, BYTE, WORD, DWORD, LWORD)
•
TIME and TIME_OF_DAY
The variables that can be selected for a measurement are configured via the
variable’s monitor. If no groupings were created in the variable’s monitor, no
variables are available. Parameters can be manually added by entering them
into the field parameter and subsequent confirmation of the addition.
NOTE
Variable names can also be directly inserted into the Parameter field by
taking them from the IO-monitor via the clipboard (Insert key of the virtual
keyboard).
7-25
SCREEN FUNCTIONALITY
E-Drive Controller User Manual (with Pendant HMI)
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.