6-19
SEVG PLUS ACTUATOR
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
Dura+ User Manual
10.
Insert four SHCSM6X90 from the motor mount flange to the valve disk
flange and torque to 18 Nm [13 ft-lbs].
1. SHCSM6X90
2. Motor mount flange
3. Valve disk flange
1
2
3
Figure 6-23 Insert the screws to fasten the assembly
6.11.3 Attach the Water Lines (Cooled Models Only)
CAUTION
Ensure that excess force is not exerted on the interface between the fitting
and the aluminum motor casing. Follow instructions below.
CAUTION
For systems with the SE40-20C model, the water lines must be connected.
This timing of the step is system dependent, and it is the responsibility of the
integrator.
Use a Torque Wrench
• torque should not exceed 22 ft. lb. for solid pipe attachment or for
swivel nut / hose connections
Use Flats From Wrench Resistance Method
• do not exceed
2 flats for tube connections to the fitting
• do not exceed
1.5 flats
for swivel nut / hose connections
Install the Motor and Valve Pin Assembly - continued
Содержание Dura PLUS
Страница 1: ...version 2 Dura User Manual Original Instructions User Manual...
Страница 2: ......