5-7
ASSEMBLY
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
Dura+ User Manual
4. Apply anti-seize compound to the nozzle threads and then thread the
nozzle into the flange. Torque nozzles to the following values:
For Hecto Nozzles: torque value is 135Nm (100 ft lb)
For Mega Nozzles: torque value is 183Nm (135 ft lb)
Remember to re-torque at process temperature when system assembly is
complete.
5.
Insert five spring clips (SPRG15) into the M6 shoulder bolt
(SHSSM6X25), and apply anti-seize compound to the thread.
Nozzle Flange Assembly - continued