9-2
Dura+ User Manual
SYSTEM INSTALLATION
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
9.2.2 Install Sub-Manifold Assembly
CAUTION
Match drop numbers stamped on bridge during assembly.
CAUTION
1.
Measure and confirm height as specified on General Assembly drawing.
2. Insert nozzle into seating bore or water cooling nozzle jacket, ensuring
that the anti-rotation dowel is engaged in the slot.
3. Take care not to pinch the wires.
4. Remove any installation tools used.
5. Apply anti-seize compound to the four system screws and install.
6. Torque system screws in a crossing pattern, gradually increasing torque to
specified value. Refer to the General Assembly drawing for torque values.
7.
Measure and confirm the angled sub-manifold height as specified on the
General Assembly drawing.
8. Repeat for each drop.
9.2.3 Install Manifold Locator and Anti-Rotation Dowel
CAUTION
Ensure sufficient gap between the dowel and the manifold slot top surface.
Under no circumstances should they touch.
CAUTION
NOTE
Check the General Assembly drawing for information for your system.
1. For some systems, locators are supplied oversize and must be ground to
the same level as the top of the nozzles. Remove the material from the
bottom face of the locator (FACE Y). Please check the General Assembly
drawing for exception notations.
FACE Y
Figure 9-1 Locator surface
2. Using a depth micrometer, verify the dimensions of the manifold pocket to
those specified on the print.
3. Apply die spotting blue the manifold locator into the bore to ensure proper
seating.