© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
5.10 Bridge Assembly
5.10.1 Installation of Inlet Components
CAUTION
For all inlet components it is important that the mold locating ring is
touching the inlet component just enough for sealing the area. This should
be double checked with the system drawings.
Ensure the machine nozzle opening matches the melt entrance for the Hot
Runner system, or is not more than 1.0 mm (0.040”) smaller.
CAUTION
The following procedures refer to different system configurations. Refer to
your parts list and General Assembly drawings to determine your system
type.
5.10.2 Heated Back Plate Installation
The center heater may require the machine nozzle radius to be added.
1. Check the machine nozzle radius.
2. Check the seating on the bottom face of the back plate and manifold
using die spotting blue compound.
3.
Clean die spotting blue compound off all components.
4. Place the center heater on the manifold.
5. Rotate the center heater to align with the tapped holes in the manifold
and align terminals with cutout.
6. Install mounting screws through the center heater into the tapped holes of
the manifold. Use anti-seize compound on the screws.